蔡东升,黄琦,李坚,易建波,胡维昊,滕予非.基于改进型IQC算法的时延电力系统控制方法研究[J].电测与仪表,2019,56(1):15-21.
Cai Dongsheng,Huang Qi,Li Jian,Yi Jianbo,Hu Weihao,Teng Yufei.Research on Control Method of Power System with Time-Delays Based on an improved IQC Algorithm[J].Electrical Measurement & Instrumentation,2019,56(1):15-21.
基于改进型IQC算法的时延电力系统控制方法研究
Research on Control Method of Power System with Time-Delays Based on an improved IQC Algorithm
DOI:
中文关键词:  时延电力系统  稳定性  时延反馈  二次积分约束
英文关键词:power system with time delays, stabilization, multiple delays feedback controller, Integral Quadratic Constraints  
基金项目:国家重点研发计划(2017YFB0902002)
                 
作者中文名作者英文名单位
蔡东升Cai Dongsheng电子科技大学
黄琦Huang Qi电子科技大学
李坚Li Jian电子科技大学
易建波Yi Jianbo电子科技大学
胡维昊Hu Weihao电子科技大学
滕予非Teng Yufei国网四川省电力公司电力科学研究院
摘要点击次数: 1668
中文摘要:
      通信时延会影响广域电力系统的稳定性,是控制系统性能恶化或者失效的重要原因之一。本文首先建立了计及时延的电力系统微分方程模型,提出基于改进型积分二次约束(Integral Quadratic Constraint, IQC)算法的时延电力系统稳定分析与控制方法。相比于传统IQC算法,该方法约束时延电力系统的输入输出,利用IQC和耗散不等式相结合的方法来设计时延反馈控制器,稳定性判据的保守性更好。文章以IEEE 两区域四机系统为例,采用DSATOOLS 的TSAT进行仿真,结果表明所提出的方法有效地减小振荡并降低时延对电力系统稳定性的影响。
英文摘要:
      Communication time delay is detrimental to power system stability and a main reason of the performance deterioration or failure for the control systems. The paper starts with modeling of the power system based on time-delay differential algebraic equations. A method based on an improved Integral Quadratic Constraints (IQC) is constructed to guarantee the stability and control of power system with time-delays. Compared with the original IQC method, this method utilizes IQC algorithm to confine the input and output of time-delayed states of power system. Besides, a combination of IQC method and dissipation inequality is proposed to design the IQCC (IQC controller), thus, the stability criterion is more conservative. A two-area four-machine power system is built to conduct the simulation based on the TSAT software of DSATOOLS. The simulation results indicate that the proposed method can effectively damp the oscillation and weak the impact of time-delay on stability of power system.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司