潘俊涛,郭小璇.考虑费控电能表信息安全交互的IPTP时钟同步技术[J].电测与仪表,2018,55(22):147-152.
Pan Juntao,Guo Xiaoxuan.The Time Synchronization of Cost Control Electricity Meter Uncertain the Information Security Interaction Mode[J].Electrical Measurement & Instrumentation,2018,55(22):147-152.
考虑费控电能表信息安全交互的IPTP时钟同步技术
The Time Synchronization of Cost Control Electricity Meter Uncertain the Information Security Interaction Mode
DOI:
中文关键词:  IPTP  时间同步  计量自动化系统  费控电能表
英文关键词:IPTP, Time  Synchronization, Measurement  Automation System, Cost  Control Electricity  Meter
基金项目:
     
作者中文名作者英文名单位
潘俊涛Pan Juntao广西电网有限责任公司电力科学研究院
郭小璇Guo Xiaoxuan广西电网有限责任公司电力科学研究院
摘要点击次数: 1267
中文摘要:
      随着分时电价在电力市场环境下应用日趋广泛,供用双方对电能表内置时钟的准确性有了更高要求。针对当前广泛使用的费控电能表时钟不一致问题,本文提出了一种考虑费控电能表信息安全交互模式的IPTP(improved PTP, IPTP)时钟同步机制。首先,通过分析费控电能表时钟不一致的原因,给出计量自动化系统“主站-计量终端-电能表”及“主站-电能表”两种时间同步方案;然后,考虑费控电能表信息安全交互模式,提出两种费控电能表IPTP时钟同步机制;最后,利用两种IPTP时钟同步机制分析费控时钟调整效果,并与传统对时模式相比。工程试验结果表明两种方法具备较好的互补特性,结合使用能较好地实现费控电能表的时钟同步,而且对时效率和准确率高,具有广阔的应用前景。
英文摘要:
      With the increasingly application of TOU in electricity market, the electricity meter has higher requirements for the accuracy of the built-in clock. Aiming at the problem of clock inconsistency in electricity meter based on TOU, this paper proposed a time synchronization of cost control electricity meter uncertain the information security interaction mode. Firstly, By analyzing the reason of clock inconsistency of the cost electricity meter, the “master station-metering terminal-electricity meter” and “master station-electricity meter” layered design are presented. Secondly, taking the information security interactive mode of cost control electricity meter into consideration, two time synchronization methods are proposed. Finally, the two time synchronization methods are used to analyze the clock adjustment effect of cost control electricity meter clock, and used to compare with the traditional time mode. The engineering test results show that the two proposed methods have better complementary characteristics. The combination of the two methods can achieve the clock synchronization of the power-controlled energy meter well, and have wide application prospects, which have wide application prospects.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司