朱梦梦,林聪,曹敏,罗强,朱全聪,田鑫萃.基于绝对延时的DCCT异地同步现场校准方法及不确定度研究[J].电测与仪表,2019,56(8):51-56,63.
zhumengmeng,lincong,曹敏,luoqiang,zhuquancong,tianxincui.Research on field calibration method and uncertainty of DCCT remote synchronization based on absolute delay[J].Electrical Measurement & Instrumentation,2019,56(8):51-56,63.
基于绝对延时的DCCT异地同步现场校准方法及不确定度研究
Research on field calibration method and uncertainty of DCCT remote synchronization based on absolute delay
DOI:
中文关键词:  异地同步  绝对延时  交错并联  不确定度  直流分量  
英文关键词:Special place synchronization  absolute delay  interlaced parallel  uncertainty  DC component  
基金项目:中国南方电网公司科技项目(YNKJ00000124),云南省人培项目(KKSY20160428)。
                 
作者中文名作者英文名单位
朱梦梦zhumengmeng云南电网有限责任公司电力科学研究院
林聪lincong云南电网有限责任公司电力科学研究院
曹敏曹敏云南电网有限责任公司电力科学研究院
罗强luoqiang江苏凌创电气自动化股份有限公司
朱全聪zhuquancong云南电网有限责任公司电力科学研究院
田鑫萃tianxincui昆明理工大学 电力工程学院
摘要点击次数: 1801
中文摘要:
      直流电流互感器(DCCT)的准确性合格与否是其状态评估及现场投产验收的重要依据,对直流输电保护控制的稳定运行起着极其重要作用。但现场校准工作受试验方法、现场校准设备及关键技术等因素影响开展并不顺利。本文结合换流站实际情况,提出一种基于绝对延时的DCCT异地同步现场校准方法,针对DCCT绝对延时的现场测试进行,并研制出高准确度直流互感器现场同步校准系统。文章构建了校准系统不确定度分析模型,确保了现场校准结果的可信度。所述试验方法在±500kV永富直流工程直流电流互感器现场试验中得到应用与验证,为我国换流站直流电流互感器现场测试提供参考依据。
英文摘要:
      The accuracy of DC current transformer (DCCT) is an important basis for its state evaluation and on-site acceptance. It plays an important role in the stable operation of HVDC protection and control. However, the field calibration is not successfully carried out by the factors such as the test method, the field calibration equipment and the key technology. Combined with the actual situation of converter station, this paper proposes a DCCT based asynchronous field synchronous calibration method based on absolute delay. Aiming at the field test of DCCT absolute delay, we develop a high-accuracy DC transformer field synchronous calibration system. In this paper, an uncertainty analysis model of the calibration system is built to ensure the reliability of the calibration results.The test method is applied and verified in the field test of DC current transformer of ±500kV Yongfu DC project, providing reference for the field test of DC current transformer of converter station in China.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司