• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
初壮,徐洁,黄大为,孙陶然.计及电压波动的配电网无功优化运行[J].电测与仪表,2019,56(11):61-67,74.
Chu Zhuang,Xu Jie,黄大为,孙陶然.Reactive power optimization of distribution networks considering DGs voltage fluctuation[J].Electrical Measurement & Instrumentation,2019,56(11):61-67,74.
计及电压波动的配电网无功优化运行
Reactive power optimization of distribution networks considering DGs voltage fluctuation
DOI:
中文关键词:  分布式电源  配电网  电压波动  电压灵敏度
英文关键词:distributed  generation,distribution  networks,voltage  fluctuation,voltage  sensitivity
基金项目:国网四川省电力公司专项资助课题项目
           
作者中文名作者英文名单位
初壮Chu Zhuang东北电力大学 电气工程学院
徐洁Xu Jie东北电力大学 电气工程学院
黄大为黄大为
孙陶然孙陶然
摘要点击次数: 1375
中文摘要:
      针对由于分布式电源(Distributed Generation,DG)出力和负荷的不确定性而引起的电压波动的问题,采用电容器组、分布式电源和静止无功补偿装置(Static Var Compensator,SVC)协调控制的方法,平抑电压波动。首先,在电容器组静态优化时,运用网络参数变动定理修正系统潮流,提高潮流计算的速度,快速得到补偿后新的各节点电压。其次,对于电容器组的静态优化结果,采用谱系聚类法合并分段,满足投切开关动作次数的约束,确定各电容器组的动作时刻和补偿容量,为实时电压控制建立良好的控制环境。最后,在电容器组补偿的基础上,分析DGs、SVC无功出力极限并作为约束条件,当实时节点电压越限时,通过电压灵敏度分析计算DGs、SVC实时无功调节量,并通过算例分析验证该方法的有效性。
英文摘要:
      According to the voltage fluctuation caused by the distributed generation (DG) and load uncertainty problem of reactive power compensation device with capacitor, distributed generation and static var compensator (SVC) method of coordinated control, stabilize the voltage fluctuation. Firstly, when the static optimization of the capacitor bank is carried out, the power flow is corrected by using the parameter change theorem of the electric network, and the speed of the power flow calculation is improved, and the new node voltage is compensated quickly. Secondly, to optimize the static results of capacitor group, using hierarchical clustering method with piecewise, meet the switching action number constraints, determine the action time and the compensation capacity of each capacitor group, real-time voltage control to establish a good control environment. Finally, on the basis of capacitor bank compensation, the reactive power limit of DGs and SVC is analyzed as a constraint condition. When the real-time node voltage is limited, the real-time reactive power regulation of DGs and SVC is calculated by voltage sensitivity analysis, and through the examples to verify the validity of the method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司