张涛,钟婷婷,张斌,李林多,肖霞.评估变压器油纸绝缘受潮的电压响应方法研究[J].电测与仪表,2019,56(9):38-42.
Zhang Tao,Zhong Tingting,Zhang Bin,Li Linduo,Xiao Xia.Study on voltage response method for evaluating moisture status of transformer oil-paper insulation[J].Electrical Measurement & Instrumentation,2019,56(9):38-42.
评估变压器油纸绝缘受潮的电压响应方法研究
Study on voltage response method for evaluating moisture status of transformer oil-paper insulation
DOI:
中文关键词:  油纸绝缘  电压响应法  初始斜率  极化电导率  受潮状态
英文关键词:oil-paper insulation  voltage response method  initial slop  polarization conductivity  moisture status
基金项目:国家自然科学基金项目( 重点项目)51307097
              
作者中文名作者英文名单位
张涛Zhang Tao三峡大学电气与新能源学院
钟婷婷Zhong Tingting三峡大学电气与新能源学院
张斌Zhang Bin国网莱芜供电公司
李林多Li Linduo三峡大学电气与新能源学院
肖霞Xiao Xia三峡大学电气与新能源学院
摘要点击次数: 1288
中文摘要:
      回复电压法能有效诊断变压器油纸绝缘的状态,但测量时间过长,由此提出通过单次加压建立的极化在不同去极化时间段内的电压响应特性进行绝缘诊断的方法,省去多次加压的过程,节省了测量时间;实验研究了不同受潮状态的变压器油纸绝缘介质在不同去极化时间段的电压响应特性,结果表明,充电2000s后首次放电0.1s的电压响应初始斜率随绝缘受潮程度的增加而增大,可作为评估其受潮状态的特征量;同时通过频域分析仪测得介质的直流电导率,将其与根据首次放电初始斜率计算获得的极化电导率进行对比分析,进一步验证了该特征量的有效性。本文提出的测量方法为应用电压响应法现场快速诊断变压器油纸绝缘的受潮状态提供了一种新的研究思路。
英文摘要:
      The recovery voltage measurement method can effectively evaluate the state of transformer oil-paper insulation, but the measurement time is too long. Thus, this paper presents a method to diagnose the insulation state by the voltage response characteristic of the polarization established at one polarization time and released in different depolarization periods, which eliminates the need for multiple voltage applications, and saves the time of measurement. The characteristics of response voltage in different depolarization periods of transformer oil-paper insulation under different moisture conditions were experimentally studied. The results show that the initial slope of the voltage response which obtained by the first discharge 0.1s after charging 2000s increases with the increase of the moisture content of the insulation, which can be used as a feature to evaluate the moisture condition of the insulation. At the same time, the DC conductivity of the medium was measured by the frequency domain analyzer and compared with the polarization conductivity calculated from the initial slope of the first discharge to further prove the validity of the feature. This measurement method provides a new research idea for the use of response voltage measurement to quickly diagnose the moisture status of transformer oil-paper insulation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司