袁泽,宝海龙,周鹿鸣,张宏宇,杨建华.规模化电采暖设备对配电网电能质量的影响分析[J].电测与仪表,2019,56(1):60-68.
YUAN Ze,BAO Hailong,ZHOU Luming,ZHANG Hongyu,YANG Jianhuan.Analysis on Impacts of Large-scale Electric Heating Radiators to Power Quality of Distribution Networks[J].Electrical Measurement & Instrumentation,2019,56(1):60-68.
规模化电采暖设备对配电网电能质量的影响分析
Analysis on Impacts of Large-scale Electric Heating Radiators to Power Quality of Distribution Networks
DOI:
中文关键词:  电采暖设备  谐波含量  电压暂降  配电网
英文关键词:Electric heating radiators  harmonic contents  voltage sag  distribution networks
基金项目:
              
作者中文名作者英文名单位
袁泽YUAN Ze北京电力经济技术研究院
宝海龙BAO Hailong北京电力经济技术研究院
周鹿鸣ZHOU Luming中国农业大学信息与电气工程学院
张宏宇ZHANG Hongyu北京电力经济技术研究院
杨建华YANG Jianhuan中国农业大学信息与电气工程学院
摘要点击次数: 1785
中文摘要:
      随着“煤改电”工程的实施,大量的电采暖设备会向配电网中注入谐波电流,并在启动过程中引起电压暂降,直接影响配电网的电能质量。通过物理模型研究和负荷现场实测的方式,针对不同类型的电采暖设备所产生的谐波含量进行了差异化分析。构建了电采暖设备在配电网不同运行场景下的仿真模型,研究了规模化电采暖对配电网谐波含量及电压暂降的影响程度和限制措施。案例分析表明,随着电采暖设备负荷渗透率的增加,配电网中的谐波含量会有不同程度的提高,电压暂降问题尤其明显,需要采取设备改进和运行控制等方式缓解电采暖设备对电能质量的影响。
英文摘要:
      With the advance of the Coal-to-electricity project, the harmonic current is injected into distribution networks from a large number of electric heating radiators, and the voltage sag is simultaneously resulted in, which have an immediate impact on the power quality of the distribution networks. On the basis of physical model analysis and practical load data, the differential analysis is carried out for the harmonic contents of different types of electric heating radiators. The simulation model of the radiators is constructed under different operation conditions. The influence degrees of harmonic contents and voltage sag resulted from the radiators are then analyzed and the corresponding measures are determined. Case study shows that the harmonic contents and the voltage sag in the low voltage distribution networks increase in varying degrees with adding the permeability of the radiators. Therefore, there is a need to adopt corresponding measures including equipment improvement and operation optimization to restrain these power quality problems.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司