程平凡,曾成碧,高选杰,苗虹.基于STATCOM/ESS的光伏低压穿越控制策略[J].电测与仪表,2019,56(11):108-114,127.
Cheng Pingfan,Zeng Chengbi,Gao Xuanjie,Miao Hong.A method to improve low voltage ride through capability of PV system based on STATCOM/ESS[J].Electrical Measurement & Instrumentation,2019,56(11):108-114,127.
基于STATCOM/ESS的光伏低压穿越控制策略
A method to improve low voltage ride through capability of PV system based on STATCOM/ESS
DOI:
中文关键词:  光伏低压穿越  STATCOM  ESS  DAB直流变换器
英文关键词:LVRT  of PV  system, STATCOM, ESS, dual  active bridge  DC/DC  converter
基金项目:四川省科技厅项目
           
作者中文名作者英文名单位
程平凡Cheng Pingfan四川大学电气信息学院
曾成碧Zeng Chengbi四川大学电气信息学院
高选杰Gao Xuanjie四川大学电气信息学院
苗虹Miao Hong四川大学电气信息学院
摘要点击次数: 1330
中文摘要:
      为了提高光伏并网系统的低压穿越(Low Voltage Ride Through, LVRT)能力,本文将储能系统(Energy Storage System, ESS)和静止同步补偿器(Static Synchronous Compensator, STATCOM)组成新型功率补偿装置STATCOM/ESS引入光伏并网发电系统。当电网侧发生电压跌落时,STATCOM/ESS不但提供的无功功率可以支撑并网点电压,同时吸收多余的有功功率避免对光伏发电系统的危害,电压恢复后将储存的能量返送回电网,高效利用能源。为便于功率双向流动,STATCOM与ESS之间采用双有源主动桥(Dual Active Bridge, DAB)直流变换器连接。针对DAB变换器,本文提出一种改进的双移相控制策略,来减小DAB变换器的回流功率。仿真结果表明,本文提出的控制策略在一定范围内将回流功率限制为零,显著提升光伏并网系统的低压穿越能力,提高光伏并网系统的稳定性,具有良好的灵活性和优越性。
英文摘要:
      In order to improve the low voltage ride through (LVRT) capability of the grid-connected PV system, this paper introduces a novel power compensator STATCOM/ESS which consists of a static synchronous compensator (STATCOM) and an energy storage system (ESS) to the system. When the grid voltage drops, the STATCOM/ESS not only supplies reactive power to support the voltage of grid connection point, but also absorbs active power at the same time to avoid damaging to the PV system. After voltage recovers, it will return energy stored in ESS to system. To achieve power bidirectional flow, a dual active bridge DC/DC converter is used to connect STATCOM and ESS. For the DAB DC/DC converter, an improved double phase shift control strategy is proposed to reduce the backflow power of it. Simulation results show that the control strategy proposed in this paper is able to limit the backflow power to zero, improve the LVRT capability of PV system significantly, contribute to stability of grid and has the feasibility and the superiority.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司