范松海,陈坤燚,肖先勇,刘小江.配电网单相接地故障残余电流转移消弧方法[J].电测与仪表,2019,56(11):20-25.
Fan Songhai,Chen Kunyi,Xiao Xianyong,Liu Xiaojiang.Arc-suppression Method Based on Transferring the Residual Current of Single Phase Grounding Fault in Distribution Network[J].Electrical Measurement & Instrumentation,2019,56(11):20-25.
配电网单相接地故障残余电流转移消弧方法
Arc-suppression Method Based on Transferring the Residual Current of Single Phase Grounding Fault in Distribution Network
DOI:10.19753/j.issn1001-1390.2019.011.004
中文关键词:  消弧  消弧线圈  残余电流转移消弧  中性点非有效接地
英文关键词:arc-suppression, arc  suppression coil, arc-suppression  method based  on transferring  the residual  current, non-effectively  grounded neutral
基金项目:
           
作者中文名作者英文名单位
范松海Fan Songhai国网四川省电力公司电力科学研究院
陈坤燚Chen Kunyi四川大学
肖先勇Xiao Xianyong四川大学
刘小江Liu Xiaojiang国网四川省电力公司电力科学研究院
摘要点击次数: 1234
中文摘要:
      根据消弧线圈和故障转移灭弧装置的优缺点,提出了一种残余电流转移的消弧方法。该方法首先利用消弧线圈将故障点电流补偿到较小数值,再投入故障转移装置转移故障点的残余电流,使电弧可靠熄灭。为了避免转移装置错误投入带来负面影响,采用两级开关结构,并用限流电阻对第一级合闸电流进行限制。通过检测限流电阻的电压或电流,可实现转移装置投入正确性以及电弧是否熄灭的判别,为故障转移装置的投退提供了可靠依据。仿真结果表明,该方法能够解决消弧线圈残流过大的问题,同时也能够避免故障转移装置错误投入带来的风险。
英文摘要:
      According to the merits and drawbacks of the arc-suppression coil and the fault transfer device, an arc suppression method based on transferring residual current is proposed. The fault point current is compensated to a smaller value by arc suppression coil, and then the residual current of the fault point is transferred by the fault transfer device, so that the arc is reliably extinguished. In order to reduce the negative impact of the false action of the transfer device, a two-stage switch structure is adopted and the current-limiting resistor is used to limit the current of the first stage. By detecting the voltage or current of the current-limiting resistor, it can distinguish the correctness of the transfer device action and whether the arc is extinguished, which provides a reliable basis for the control of the fault transfer device. The simulation results show that this method can reduced the residual current of fault point and can also avoid the risk of false action.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司