田新和,陈皓,郑思琦,闫重熙,高传薪.低压双极环形直流微网的新型故障定位法[J].电测与仪表,2019,56(15):8-13,20.
tianxinhe,chenhao,Zheng Siqi,Yan Chongxi,Gao Chuanxin.A Novel Fault Location Method for Low Voltage Bipolar Ring DC Microgrid[J].Electrical Measurement & Instrumentation,2019,56(15):8-13,20.
低压双极环形直流微网的新型故障定位法
A Novel Fault Location Method for Low Voltage Bipolar Ring DC Microgrid
DOI:10.19753/j.issn1001-1390.2019.015.002
中文关键词:  低压双极环形直流微网  单极接地故障  极间短路故障  故障定位  差分法  伪逆法
英文关键词:low voltage bipolar ring DC microgrid  pole-to-ground fault  pole-to-pole fault  fault location  difference method  pseudo inverse method
基金项目:
              
作者中文名作者英文名单位
田新和tianxinhe四川大学电气信息学院
陈皓chenhao四川大学电气信息学院
郑思琦Zheng Siqi四川大学电气信息学院
闫重熙Yan Chongxi四川大学电气信息学院
高传薪Gao Chuanxin四川大学电气信息学院
摘要点击次数: 1728
中文摘要:
      当直流微网线路发生故障时,为快速切除故障并恢复供电,减少停电时间,需要快速准确的故障定位。本文以低压双极环形直流微网为研究对象,针对单极接地故障和极间短路故障,提出了一种差分法与伪逆法相结合的新型故障定位方法,可在线确定出不同故障条件下的故障位置,且定位准确性高。根据暂态期间故障回路的KVL矩阵方程,利用差分法和伪逆法,计算故障线路的等效电感,进而计算出故障距离,从而实现故障定位。通过PSCAD/EMTDC仿真验证了该方法的有效性,对两种故障类型及不同故障距离和故障电阻,故障距离估计误差均小于1.43%,故障电阻相对误差小于0.04%。该方法可针对两种不同的故障类型,不受故障距离和故障电阻的影响,能准确地确定出故障点位置并计算出故障电阻,具有较好的实用性。
英文摘要:
      When a fault occurs on DC microgrid cable, in order to achieve quick fault clearance, fast restoration, and reduction of power outage duration, it is necessary to quickly and accurately locate fault point. For pole-to-ground fault and pole-to-pole fault, a novel fault location method combining difference method and pseudo inverse method is proposed for low voltage bipolar ring DC microgrid. The proposed scheme can online locate fault point under different fault conditions, which has high location accuracy. According to the KVL matrix equation of fault circuit during transient state, the equivalent inductance of fault cable is calculated by using difference method and pseudo inverse method, and then fault distance is calculated to locate fault point. The effectiveness of the method is verified by PSCAD/EMTDC simulation. For two fault types as well as different fault distance and fault resistance, the estimated error of fault distance is less than 1.43% and the relative error of fault resistance is less than 0.04%. Not affected by fault distance and fault resistance, the proposed scheme, which is suitable for two different fault types, can accurately locate fault point and calculate fault resistance, so it has good practicability.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司