• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
戴朝波,孔飞,邓占锋,孙谊媊,于永军.半波长交流输电的串并联补偿仿真分析[J].电测与仪表,2019,56(18):86-92.
Dai Chaobo,Kong Fei,Deng Zhanfeng,Sun Yiqian,Yu Yongjun.Simulation and analysis of series and parallel compensation of half wavelength ac transmission system[J].Electrical Measurement & Instrumentation,2019,56(18):86-92.
半波长交流输电的串并联补偿仿真分析
Simulation and analysis of series and parallel compensation of half wavelength ac transmission system
DOI:
中文关键词:  半波长交流输电  过电压  并联补偿  串联补偿
英文关键词:Half  wavelength AC  transmission, over-voltage, shunt  compensation, series  compensation
基金项目:
              
作者中文名作者英文名单位
戴朝波Dai Chaobo先进输电技术国家重点实验室,全球能源互联网研究院有限公司
孔飞Kong Fei先进输电技术国家重点实验室,全球能源互联网研究院有限公司
邓占锋Deng Zhanfeng先进输电技术国家重点实验室,全球能源互联网研究院有限公司
孙谊媊Sun Yiqian国网新疆电力公司电力科学研究院
于永军Yu Yongjun国网新疆电力公司电力科学研究院
摘要点击次数: 1108
中文摘要:
      现有研究结论认为半波长交流输电线路本身无需安装无功补偿设备,然而稳态运行时半波长交流输电沿线电压分布具有其特殊性。过电压的极值和出现位置与输送功率、功率因数等密切相关。本文首先采用特高压交流线路工程参数,通过数字仿真手段分析了半波长交流线路的沿线电压分布特性,在电压和电流相量图的辅助下,着重研讨了在半波长交流线路的两端而不是线路本身进行串联补偿和并联补偿来改善沿线电压分布特性、减少线路损耗的可行性。仿真分析结果表明:半波长交流输电线路两端是需要无功补偿的;串联补偿和并联补偿都能降低半波长线路的线损率,还能改变半波长沿线电压分布;与常规线路不同,半波长线路的并联补偿能更有效地抑制稳态过电压,控制更简单。
英文摘要:
      The results of existed study show that there is no requirement for reactive compensation by Half Wavelength Al-ternating Current Transmission (HWACT) lines themselves. However, the characteristics of steady-state voltage distribution of HWACT lines are distinctive. The over-voltage maximum and its position are closely related with both transmission power and power factor. In this paper, based on parameters of existed ultra-high voltage AC transmission lines, steady-state voltage distribution characteristics of an HWACT line are firstly analyzed through digital simulation. Then with the aid of the voltage and current phasor diagram, both series compensation and shunt compensation at the terminals of the HWACT line instead of itself are proposed to improve the voltage distribution characteristics and to reduce power losses. The simulation and analysis results finally show that there are re-quirement for reactive compensation at the terminals of HWACT lines. Both series compensation and shunt com-pensation might reduce the power losses of the HWACT lines and modify the steady-state voltage distribution. The shunt compensation is more effective and easier to mitigate the steady state over-voltage of the HWACT line than the series compensation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司