秦靖舒,范淑薇,关向雨,舒乃秋.基于Wiener过程气体绝缘母线触头接触失效预测[J].电测与仪表,2019,56(24):7-12.
Qin Jingshu,Fan Shuwei,Guan Xiangyu,Shu Naiqiu.Contact failure prediction of Gas Insulated Bus contact on Wiener process[J].Electrical Measurement & Instrumentation,2019,56(24):7-12.
基于Wiener过程气体绝缘母线触头接触失效预测
Contact failure prediction of Gas Insulated Bus contact on Wiener process
DOI:10.19753/j.issn1001-1390.2019.024.002
中文关键词:  GIB触头  非线性Wiener退化模型  加速老化试验  寿命预测
英文关键词:contact  of GIB, nonlinear  Wiener degradation  model, accelerated  aging test, life  prediction
基金项目:中国博士后科学基金
           
作者中文名作者英文名单位
秦靖舒Qin Jingshu武汉大学 电气工程学院
范淑薇Fan Shuwei国网郑州供电公司
关向雨Guan Xiangyu武汉大学 电气工程学院
舒乃秋Shu Naiqiu武汉大学 电气工程学院
摘要点击次数: 1324
中文摘要:
      气体绝缘母线(GIB)触头是过热性故障的多发部位,而接触电阻的大小是设备能否稳定运行的决定性因素。为了实现对GIB触头接触失效的预测,本文首先在时间尺度的非线性Wiener模型与逆幂率加速老化模型基础上,建立了GIB触头的失效预测模型。搭建了GIB触头电接触失效试验平台,开展了SF6和空气介质下GIB触头的载流摩擦磨损试验。通过似然函数参数估计得到不同条件下GIB触头接触电阻退化表达式,进而根据概率分布函数获取触点的接触失效寿命。试验结果与预测结果对比表明所建立失效预测模型的有效性。GIB触点在空气下的寿命22.76年,在SF6下的寿命为43.67年,所建立的失效预测模型可为GIB触头的设计制造和状态检修提供技术支持。
英文摘要:
      Gas insulated bus contacts are the frequent parts of overheating faults, and the size of contact resistance is the decisive factor for the stable operation of the equipment. In order to predict the contact failure of GIB contacts, a failure prediction model of gas insulated bus contacts is established in this paper based on the nonlinear Wiener model of time scale and the inverse power rate accelerated aging model. A test platform for electric contact failure of gas insulated bus contacts was set up, and a test of current-carrying friction and wear of gas insulated bus contacts under SF6 and air media was carried out. The contact resistance degradation expression of gas insulated busbar contacts under different conditions is obtained by the likelihood function parameter estimation. The comparison between the test results and the prediction results shows that the proposed failure prediction model is effective.The service life of GIB contacts under air is 22.76 years, and the service life under SF6 is 43.67 years. The failure prediction model established can provide technical support for the design, manufacture and maintenance of GIB contacts.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司