徐文佳,项祖涛,杨大业.基于电流互感器的长距离GIL短路故障在线定位方法研究[J].电测与仪表,2019,56(21):122-128.
XU Wen-jia,XIANG Zu-tao,YANG Da-ye.On-line Short-Circuit Fault Location Method for GIL Based on Current Transformer[J].Electrical Measurement & Instrumentation,2019,56(21):122-128.
基于电流互感器的长距离GIL短路故障在线定位方法研究
On-line Short-Circuit Fault Location Method for GIL Based on Current Transformer
DOI:10.19753/j.issn1001-1390.2019.021.020
中文关键词:  GIL  电流  电流互感器  短路故障  在线定位
英文关键词:GIL, current, current  transformer, short-circuit  fault, on-line  location
基金项目:国家电网公司科技项目《特高压GIL与架空混合输电线路的系统运行特性研究》
        
作者中文名作者英文名单位
徐文佳XU Wen-jia中国电力科学研究院有限公司
项祖涛XIANG Zu-tao中国电力科学研究院有限公司
杨大业YANG Da-ye中国电力科学研究院有限公司
摘要点击次数: 1817
中文摘要:
      气体绝缘金属封闭输电线路(gas insulated metal-enclosed transmission line,GIL)内部发生短路故障后,如何在线准确、快速地确定故障位置,缩短故障后的检修时间,对电网的安全稳定运行至关重要。本文通过分析汇流排处电流互感器检测到的电流的特征,提出一种基于汇流排电流的长距离GIL短路故障在线定位方法。首先从理论上计算了GIL发生短路故障时,流过各电流互感器电流的特征;然后分析了GIL接入的架空线发生接地故障时,各电流互感器测得的电流分布,在此基础上,利用故障点两侧电流互感器的测量结果,制定出GIL短路故障的在线定位判据。还针对当短路故障位于GIL首/末段时无法精确定位的特殊情况,提出应缩短GIL首/末段两侧电流互感器的安装距离。本文提出的定位方法只与位于故障点两侧最近的两电流互感器测得的电流幅值有关,原理简单,结果准确。最后,以苏通GIL综合管廊工程为例,验证并说明了本文所提出方法及结论的正确性与有效性。
英文摘要:
      How to determine the fault location on-line accurately and rapidly to reduce the recovery time, when there is internal short-circuit fault in gas insulated metal-enclosed transmission line (GIL), is of most emergent importance to the safety operation of power network. With each bus-bar of GIL shell equipped with a current transformer, we can realize on-line short-circuit fault location for GIL based on current detection. Firstly, current characteristics in current transformer when a short-circuit fault occurs are discussed theoretically. Then, current distributions of current transformers under short-circuit faults of overhead line are analyzed. By using the results of current transformers equipped at both sides of fault section, we propose the on-line locating criterion for short-circuit fault of GIL. In terms of special instances, that faults cannot be located precisely which are in the first/last section of GIL, shortening the distance between two current transformers equipped at first/last section of GIL should be considered. The results of this method presented in paper are determined only by current amplitude of current transformers equipped at both sides of fault section, which is simple and reliable. Finally, Su-Tong GIL pipe gallery project is taken as an example for simulation, the conclusions of this paper are further verified.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司