高选杰,苗虹,曾成碧,熊正勇.提高光伏并网逆变器在弱电网下稳定性的阻抗相角补偿控制[J].电测与仪表,2019,56(22):1-6.
Gao Xuanjie,Miao Hong,Zeng Chenbi,Xiong Zhengyong.Impedance phase angle compensation control for improving stability of photovoltaic grid connected inverter in weak grid[J].Electrical Measurement & Instrumentation,2019,56(22):1-6.
提高光伏并网逆变器在弱电网下稳定性的阻抗相角补偿控制
Impedance phase angle compensation control for improving stability of photovoltaic grid connected inverter in weak grid
DOI:10.19753/j.issn1001-1390.2019.022.001
中文关键词:  并网逆变器  弱电网  惯性反馈  相角补偿  相角裕度  谐波总畸变率  
英文关键词:grid-connected inverter  weak grid  inertial feedback  phase angle compensation  phase margin  total harmonic distortion rate  
基金项目:四川省科技厅资助(2018GZ0394)
           
作者中文名作者英文名单位
高选杰Gao Xuanjie四川大学电气信息学院
苗虹Miao Hong四川大学电气信息学院
曾成碧Zeng Chenbi四川大学电气信息学院
熊正勇Xiong Zhengyong四川大学电气信息学院
摘要点击次数: 1361
中文摘要:
      针对LCL型并网逆变器自身存在的谐振现象,提出一种电容电压惯性反馈控制策略来抑制其谐振尖峰。在弱电网情况下,由于电网阻抗和并网逆变器输出阻抗的相互作用,使得并网逆变器的稳定性急剧恶化。于是提出输出阻抗相角补偿加滤波器的方法,提高逆变器输出阻抗相角使其满足稳定裕度,从而提高并网逆变器在弱电网下的稳定性。在MATLAB/Simulink仿真平台上搭建并网逆变器系统仿真模型,对所提方法进行仿真验证。仿真结果表明,所提方法不仅能提高并网逆变器的稳定性,而且还能改善并网电流的质量,降低谐波总畸变率。
英文摘要:
      Aiming at the resonance phenomenon of grid-connected inverter with LCL, an inertial feedback control strategy based on capacitor voltage is proposed to suppress the resonance peak. However, in the case of weak grid, the stability of grid-connected inverter deteriorates sharply due to the interaction between the grid impedance and the output impedance of grid-connected inverter. Therefore, a phase angle compensation method with filter is proposed to improve the output impedance phase angle of the inverter to meet the stability margin, thus improve the stability of grid connected inverter in weak grid. The simulation model of grid connected inverter system is built on MATLAB/Simulink platform and the proposed method is verified by simulation. The results show that the proposed method can not improve the stability of grid connected inverter, but also improve the quality of grid connected current and reduce the total harmonic distortion rate (THD).
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司