• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
陈 缨,陈坤燚,肖先勇,杨 琳,范松海,陈少卿.负荷对接地故障转移消弧技术的影响[J].电测与仪表,2019,56(23):24-30.
Chen Ying,Chen Kunyi,Xiao Xianyong,Yang Lin,Fan Songhai,Chen Shaoqing.Effects of Load on Arc-suppression Method Based on Grounded-Fault Transfer Device[J].Electrical Measurement & Instrumentation,2019,56(23):24-30.
负荷对接地故障转移消弧技术的影响
Effects of Load on Arc-suppression Method Based on Grounded-Fault Transfer Device
DOI:10.19753/j.issn1001-1390.2019.023.004
中文关键词:  消弧  接地故障转移转移消弧  中性点非有效接地  负荷阻抗
英文关键词:arc-suppression, arc-suppression  method based  on grounded-fault  transfer device, non-effectively  grounded neutral, load  impedance
基金项目:
                 
作者中文名作者英文名单位
陈 缨Chen Ying国网四川省电力公司电力科学研究院
陈坤燚Chen Kunyi四川大学 电气信息学院
肖先勇Xiao Xianyong四川大学 电气信息学院
杨 琳Yang Lin国网四川省电力公司电力科学研究院
范松海Fan Songhai国网四川省电力公司电力科学研究院
陈少卿Chen Shaoqing国网四川省电力公司电力科学研究院
摘要点击次数: 1383
中文摘要:
      为了分析负荷对接地故障转移消弧技术的影响,提出了一种接地故障转移消弧技术等效模型。利用该模型对接地故障转移消弧装置的电流转移性能和恢复电压抑制能力进行了研究,给出了接地故障转移消弧技术受负荷影响的规律。研究结果表明:接地故障转移消弧装置的电流转移性能受负荷影响较大,在大负荷、小接地电阻的情况下可能出现不能转移故障点电流的情况,甚至有增大故障点电流的可能;故障转移消弧装置对恢复电压有较强的抑制能力,且受负荷的影响较小。研究结果为接地故障转移消弧装置控制方法的改进提供了理论依据。
英文摘要:
      In order to analyze the effects of load on arc-suppression method based on grounded-fault transfer device, an equivalent model of the arc-suppression method was proposed. The performance for transferring fault current and the capacity for controlling recovery voltage of the transfer device were studied by using the proposed model, and the laws of the arc suppression method affected by load was given. The results show that it has a great effect by load on the performance for transferring fault current. In the case of large load and small ground resistance, it is possible that the fault current cannot be transferred, or even the fault current can be increased. In addition, the analysis results indicated that the ground fault transfer device has a strong ability to restrain the recovery voltage, and is less affected by the load. The results provide a theoretical basis for improving the control method of the arc suppression device.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司