侯思祖,郭威.基于自适应陷波滤波器和混沌振子的配电网故障选线[J].电测与仪表,2020,57(6):61-66.
Hou Sizu,Guo Wei.Application of Adaptive Notch Filter and Chaos Oscillator to Fault Line Detection in Distribution Network[J].Electrical Measurement & Instrumentation,2020,57(6):61-66.
基于自适应陷波滤波器和混沌振子的配电网故障选线
Application of Adaptive Notch Filter and Chaos Oscillator to Fault Line Detection in Distribution Network
DOI:10.19753/j.issn1001-1390.2020.06.010
中文关键词:  自适应陷波滤波器  混沌振子  尺度变化  五次谐波  
英文关键词:adaptive notch filter, chaos oscillator, time scale transformation, fifth harmonic wave
基金项目:
     
作者中文名作者英文名单位
侯思祖Hou Sizu华北电力大学
郭威Guo Wei华北电力大学
摘要点击次数: 1576
中文摘要:
      小电流系统发生单相接地故障时,各馈线的零序电流呈现出复杂的非线性和非平稳性,故障点的信号电流也非常微弱,给故障选线带来困难。但故障后,故障馈线的零序高频分量幅值是所有正常馈线之和,且相位相反。文中提出一种结合自适应陷波滤波器(Adaptive Notch Filter, ANF)和混沌振子的选线方法。ANF可以通过调节本身参数,实时、准确的提取各馈线高频信号,而混沌振子对内外同频率信号有较高敏感性,对其进行尺度变化以适应电网高频信号检测。首先通过ANF提取故障零序电流中五次谐波,将其作为混沌振子的输入,用获得的系统相图作为故障判据。对不同条件下的故障进行了仿真验证,结果证明了算法的准确性。
英文摘要:
      When a single-phase-to-ground fault occurs in a small current system, the zero-sequence current of each feeder presents complex nonlinearity and nonstationarity, and the signal current at the fault point is very weak, which brings difficulties to fault line selection. However, after fault, the zero sequence high frequency component of fault feeder is larger than that of normal feeder, and the phase is opposite. In this paper, a line selection method combining adaptive notch filter and chaotic oscillator is proposed. By adjusting its parameters, ANF can extract high-frequency signals from feeders in real time and accurately. Chaotic oscillator is more sensitive to the same frequency signals inside and outside, and its scale changes to adapt to high-frequency signal detection of power grid. Firstly, the fifth harmonic of fault zero-sequence current is extracted by ANF, which is used as the input of chaotic oscillator. The obtained system diagram is taken as the fault criterion. Simulation results show that the algorithm is accurate.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司