岳长喜,朱凯,李智成,高翔.基于间接带电作业法的6-35 kV高压计量现场校验装置研究[J].电测与仪表,2020,57(7):147-152.
Yue Changxi,Zhu Kai,Li Zhicheng,Gao Xiang.Research on 6-35 kV high voltage measurement field calibration device based on indirect live work method[J].Electrical Measurement & Instrumentation,2020,57(7):147-152.
基于间接带电作业法的6-35 kV高压计量现场校验装置研究
Research on 6-35 kV high voltage measurement field calibration device based on indirect live work method
DOI:10.19753/j.issn1001-1390.2020.07.023
中文关键词:  高压配网计量装置  带电作业  综合误差
英文关键词:high-voltage  metering device, live  line working, integrated  error
基金项目:国家电网公司科技项目,配电网计量装置运行性能诊断与综合评价关键技术研究(JL71-17-004)
           
作者中文名作者英文名单位
岳长喜Yue Changxi中国电力科学研究院
朱凯Zhu Kai中国电力科学研究院
李智成Li Zhicheng中国电力科学研究院
高翔Gao Xiang珠海安瑞通电子科技有限公司
摘要点击次数: 1694
中文摘要:
      随着国家对电网线损精细化管理要求的提出,通过增加智能计量装置来提高线损管理水平就显得十分必要了。近年来,低压配电网的计量装置(主要是低压智能电表)的普及布设已经相当完善,其检定及现场校验的规程和手段也都已经相当完善。但是,高压配电网(6-35 kV)的计量装置由于电网公司对停电考核指标的要求越来越高,其增加或者汰换的速度远不及低压计量表计;由于无法停电,现场运行多年的高压计量装置的现场校验工作通常只针对了低压表计部分,而高压PT、CT的现场校验工作往往无法实施。这样高压计量装置的现场整体综合误差就没有一种手段能够获得。本文通过分析现有高压配电网计量装置运行中的状态,研究了一种新型的可带电作业的现场校验装置。不仅能够整体对现有运行中的高压配网计量装置进行带电校验,还能够在5~500 A的动态范围内,达到有功0.1级的精度。
英文摘要:
      With the requirement of meticulous management of power line loss put forward by our country, it is necessary to increase the level of line loss management by adding intelligent metering devices. In recent years, the common layout of low-voltage distribution network metering devices (mainly low-voltage smart meters) has been quite perfect, and the rules and means of its verification and field calibration have been quite perfect. But, As the power grid company"s requirements for the power failure assessment indicators are getting higher and higher, the rate of increase or replacement of high-voltage (6-35 kV) metering devices is far less than that of low-voltage meters. Because of unable power cutting, field calibration of high-voltage metering devices that have been in operation for many years only at the meter section, not including the PT, CT. So, there is no means to obtain the integrated error of the high-voltage metering device. In this paper, a new type of on-site calibration device for live operation is studied by studying the operation status of existing metering devices in high-voltage distribution network. It can not only field calibrate the existing high-voltage metering devices, but also achieve the accuracy of 0.1 level of active power in the dynamic range of 5-500 A.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司