汪晓华,唐明,宋玮琼,羡慧竹,连利波,王剑.满足国家电网公司标准体系下的LoRa用能采集专网技术研究及应用[J].电测与仪表,2020,57(8):8-12.
Wang Xiaohua,Tang Ming,Song Weiqiong,Xian Huizhu,Lian Libo,Wang Jian.Research and Application of Dedicated LoRa Electrical Energy Acquisition Network Under State Grid Standard System[J].Electrical Measurement & Instrumentation,2020,57(8):8-12.
满足国家电网公司标准体系下的LoRa用能采集专网技术研究及应用
Research and Application of Dedicated LoRa Electrical Energy Acquisition Network Under State Grid Standard System
DOI:10.19753/j.issn1001-1390.2020.08.002
中文关键词:  国网用采标准  LoRa  SNR  组网  地下车库充电桩
英文关键词:electrical energy acquisition, LoRa, SNR, dedicated network  
基金项目:
                 
作者中文名作者英文名单位
汪晓华Wang Xiaohua清华四川能源互联网研究院
唐明Tang Ming清华四川能源互联网研究院
宋玮琼Song Weiqiong国网北京市电力公司电力科学研究院
羡慧竹Xian Huizhu国网北京市电力公司电力科学研究院
连利波Lian Libo清华四川能源互联网研究院
王剑Wang Jian清华四川能源互联网研究院
摘要点击次数: 1592
中文摘要:
      本文首先分析了现有采集技术在地下车库充电桩、煤改电等复杂、多变、新型、弱规划应用场景下采集难的原因。之后,对比分析了LoRa技术优势,提出了基于国网用采标准体系的LoRa用能采集专网架构。然后,建立了基于“多叉树”模型的LoRa网络,将节点接收信噪比纳入通信质量考核指标,提出了最大可靠路径组网策略和最优路径组网策略。在若干小区地下车库建设LoRa专网,经测试,地下车库范围内的LoRa网络覆盖率达到100%,良信号以上信号覆盖率达100%,一周连续抄表成功率为100%。LoRa用能采集专网方案得充分验证。
英文摘要:
      Firstly, this paper explains why the current electrical energy acquisition technology is not very suitable in the complex, variable, new type, and weak planning application environment. After that, the advantages of LoRa technology are compared and analyzed, and the dedicated LoRa electrical energy acquisition network architecture based on the State Grid standard system is proposed. Then, a LoRa network based on "multi-forked tree" model is established. When assessing the communication quality, the paper takes the slave node receiving signal-to-noise ratio into consideration and proposes the Max Reliable Route Network(MRRN) and Best Route Network(BRN). To verify the dedicated LoRa network’s reliability, the network was built in several underground garages. The result shows that the coverage of LoRa signal reaches 100%, the area with good LoRa signal quality reaches 100%, and the success rate of continuous meter reading in a week reaches 100%.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司