廖巍,田昊洋,胡敏,陈海昆,袁鑫锋,金之俭.突发短路试验中变压器振动监测系统的设计[J].电测与仪表,2020,57(9):110-116,127.
Liao Wei,Tian Haoyang,Hu Min,Chen Haikun,Yuan Xinfeng,Jin Zhijian.Design of a vibration monitoring system for power transformer in short-circuit test[J].Electrical Measurement & Instrumentation,2020,57(9):110-116,127.
突发短路试验中变压器振动监测系统的设计
Design of a vibration monitoring system for power transformer in short-circuit test
DOI:10.19753/j.issn1001-1390.2020.09.017
中文关键词:  突发短路  变压器振动  绕组形变  分布式系统
英文关键词:Burst short circuit, vibration of power transformer, winding deformation, distributed System
基金项目:国网上海市电力公司电力科学研究院2018年科技项目(520940170028)
                 
作者中文名作者英文名单位
廖巍Liao Wei国网上海市电力公司电力科学研究院
田昊洋Tian Haoyang国网上海市电力公司电力科学研究院
胡敏Hu Min上海交通大学电气工程系
陈海昆Chen Haikun上海市南电力(集团)有限公司
袁鑫锋Yuan Xinfeng上海交通大学电气工程系
金之俭Jin Zhijian上海交通大学电气工程系
摘要点击次数: 1662
中文摘要:
      突发短路试验能够对变压器的抗短路能力进行评估,而绕组在试验中是否发生形变是重要的判断标准。基于振动分析法的绕组状态检测技术具有灵敏度高、工作效率高等优点,但现有的变压器振动采集系统不能满足短路试验中对采集精度和防护标准的要求,文中设计了分布式变压器振动采集系统,在试验间内安装高防护等级、高精度的采集单元,将采样得到的振动信号就地转换为数字信号发送至控制室内的主控单元,避免短路试验中恶劣的电磁环境对采样信息产生干扰。后期可通过计算机对振动信号进行处理来分析绕组健康状态,目前系统已成功投入应用。
英文摘要:
      The short-circuit test can evaluate the short-circuit resistance of the transformer, and whether the winding is deformed during the test is an important criterion. The winding state detection technology based on vibration analysis has the advantages of high sensitivity and high working efficiency, but the existing transformer vibration acquisition system cannot meet the requirements of acquisition accuracy and protection standards in the short circuit test. In this paper, a distributed transformer vibration acquisition system is designed. A high-protection level and high-precision local unit is installed in the test room. The collected vibration signal is converted into a digital signal and sent to the main control unit in the control room to avoid the short-circuit test. The harsh electromagnetic environment interferes with the sampling information. In the later stage, the vibration signal can be processed by computer to analyze the health status of the winding. The system has been successfully put into use.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司