刘梦华,赵伟,黄松岭,史坤鹏.对多机并联下应用频移式孤岛检测法面临问题的探讨[J].电测与仪表,2019,56(21):1-7.
Liu Menghua,Zhao Wei,Huang Songling,Shi Kunpeng.Discussion on two issues of frequency shift islanding detection methods in multi-DG operation[J].Electrical Measurement & Instrumentation,2019,56(21):1-7.
对多机并联下应用频移式孤岛检测法面临问题的探讨
Discussion on two issues of frequency shift islanding detection methods in multi-DG operation
DOI:10.19753/j.issn1001-1390.2019.021.001
中文关键词:  孤岛检测  频率偏移  无功功率扰动  逆变器比例  正反馈增益
英文关键词:islanding detection, frequency shift, reactive power disturbance, rate of inverters, positive feedback gain
基金项目:
           
作者中文名作者英文名单位
刘梦华Liu Menghua清华大学电机系
赵伟Zhao Wei清华大学电机系
黄松岭Huang Songling清华大学电机系
史坤鹏Shi Kunpeng清华大学电机系
摘要点击次数: 1393
中文摘要:
      针对目前广泛应用的频移式孤岛检测方法——简称频移法,指出当只有部分逆变器采用该方法时,其扰动能力可能不足以撼动孤岛的频率并使其超限,从而提出采用频移法的逆变器比例和频移法正反馈增益的调节等2个问题。针对采用频移法的逆变器比例问题,在最不利情况下进行分析,获得了该比例与逆变器最大过载倍数之间的关系,发现逆变器过载能力越大,采用频移法的逆变器比例可越小;关于频移法正反馈增益的调节问题,本文推导出了正反馈增益与采用频移法逆变器比例的关系,表明正反馈增益必须根据采用频移法的逆变器的比例同步增大。仿真结果验证了上述结论。
英文摘要:
      For frequency shift islanding detection method (simply referred to as frequency shift method), a very common active method, it is pointed out that if only parts of inverters employ this method, their disturbance strength may be unable to cause the frequency to exceed the limit. And then two related issues are raised: the rate of the inverters employing frequency shift method and the adjustment of positive feedback gain of frequency shift method. For the rate of the inverters employing frequency shift method, in the most unfavorable case, a relationship between it and the maximum overload factor of an inverter is achieved. The relationship shows that this rate can be smaller if the overload capability of inverters are larger. For the adjustment of positive feedback gain of frequency shift method, a relationship between it and the rate of the inverters employing frequency shift method is obtained. This relationship shows that the positive feedback gain should increase according to the rate of the inverters employing frequency shift method. Simulations are performed and verify the previous conclusions.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司