This paper proposes to use the principle of electromagnetic induction, design the electromagnetic coil to induce voltage, drive the LED luminescent tube to emit light, observe the brightness of the luminescent tube can be judged whether the discharge tube fault or not, and show the fault of the tube, to provide the indicating function for maintenance.The feasibility is verified by theory and experiment, and a reliable fault diagnosis system for discharge tube of ozone generator is designed.