明潇宇,吕飞鹏,余晓,王珊珊.含T接逆变型分布式电源配电网的纵联保护方案[J].电测与仪表,2020,57(11):74-79.
Ming Xiaoyu,Lv Feipeng,Yu Xiao,Wang Shanshan.Pilot protection scheme for distribution network with T-connectedinverter interfaced distributed generation[J].Electrical Measurement & Instrumentation,2020,57(11):74-79.
含T接逆变型分布式电源配电网的纵联保护方案
Pilot protection scheme for distribution network with T-connectedinverter interfaced distributed generation
DOI:10.19753/j.issn1001-1390.2020.11.012
中文关键词:  逆变型分布式电源  T接线路  纵联保护  复合差动阻抗  配电网
英文关键词:inverter  interfaced distributed  generation, teed  line, pilot  protection, composite  differential impedance, distribution  network
基金项目:
           
作者中文名作者英文名单位
明潇宇Ming Xiaoyu四川大学 电气信息学院
吕飞鹏Lv Feipeng四川大学 电气信息学院
余晓Yu Xiao四川大学 电气信息学院
王珊珊Wang Shanshan四川大学 电气信息学院
摘要点击次数: 1607
中文摘要:
      针对逆变型分布式电源(IIDG)T接方式接入配电网后传统三段式电流保护难以适用的问题,提出了一种含T接逆变型分布式电源配电网的纵联保护方案。该方案首先讨论了在低电压穿越期间IIDG采用恒功率控制策略对故障输出的影响;其次,通过定义复合差动阻抗并分析其在被保护馈线区内外故障的幅值差异,提出一种基于复合差动阻抗的含逆变电源T接配网的纵联保护原理;同时,为消除该保护原理在三相金属性短路故障时的死区,引入T型电流差动保护作为辅助判据。最后,在PSCAD/EMTDC仿真平台搭建了含IIDG的10kV配电网仿真模型,仿真结果验证了本文方案的合理性与有效性。
英文摘要:
      S:Aiming at the problem that traditional three-stage current protection is difficult to be applied after inverter interfaced distributed generation(IIDG) T-shaped access to distribution network, a pilot protection scheme for IIDG T connection distribution network is proposed. The effect of constant power control strategy on fault output during low voltage crossing is discussed. Secondly, by defining the composite differential impedance and analyzing the amplitude difference of the fault in and outside the protected feeder area, the pilot protection principle of the inverter interfaced distributed generation T connection network based on the composite differential impedance is proposed. At the same time, in order to eliminate the dead zone in the three-phase gold short circuit fault, the differential current protection of T-type transmission lines is introduced as the auxiliary criterion. Finally, a 10kV distribution network simulation model with IIDG is built on the PSCAD / EMTDC simulation platform. The simulation results prove that the scheme is reasonable and effective.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司