范亚楠,刘天羽,盛戈皞,张新松,江秀臣.基于最优阻尼比虚拟同步发电机的优化控制策略[J].电测与仪表,2020,57(7):60-67.
Fan Yanan,Liu Tianyu,Sheng Gehao,Zhang Xinsong,Jiang Xiuchen.Optimal control strategy of virtual synchronous generator based on optimal damping ratio[J].Electrical Measurement & Instrumentation,2020,57(7):60-67.
基于最优阻尼比虚拟同步发电机的优化控制策略
Optimal control strategy of virtual synchronous generator based on optimal damping ratio
DOI:10.19753/j.issn1001-1390.2020.07.010
中文关键词:  微电网  虚拟同步发电机  功角特性曲线  虚拟惯量  阻尼系数
英文关键词:Microgrid, Virtual synchronous generator, Power angle curve, Virtual inertia, Damping coefficient
基金项目:国家自然科学基金资助项目(51607098,51477099)
              
作者中文名作者英文名单位
范亚楠Fan Yanan上海电机学院
刘天羽Liu Tianyu上海电机学院
盛戈皞Sheng Gehao上海交通大学
张新松Zhang Xinsong南通大学
江秀臣Jiang Xiuchen上海交通大学
摘要点击次数: 1373
中文摘要:
      针对微电网中可再生能源渗透率越来越高,微电网惯性和阻尼不足等问题越来越突出,随即一种新的控制方式即虚拟同步发电机(virtual synchronous generator,VSG)技术被提出。区别于传统同步电机,虚拟同步发电机可以实时的控制电机参数获得系统稳定。本文从传统同步发电机有功控制环出发,结合功角特性曲线和频率振荡曲线分析惯性参数和阻尼系数对系统稳定性的影响。在现有控制方式的基础上提出一种基于最优阻尼比的惯性参数和阻尼系数共同自适应的控制策略。最后在Matlab/Simlink中通过离网和并网仿真分析验证所提策略的正确性和有效性,结果证明能够有效抑制系统的系统波动并具有很好的动态性能。
英文摘要:
      In view of the increasing permeability of renewable energy in microgrid.A new control method, virtual synchronous generator (VSG), was proposed to solve the problem of insufficient inertia and damping. Unlike traditional synchronous motors, virtual synchronous generators can control motor parameters in real time to achieve system stability. In this paper, the influence of inertia parameters and damping coefficients on the system stability is analyzed by combining the power angle characteristic curve and frequency oscillation curve of traditional active power control loop of synchronous generator. Combining the existing control methods, a control strategy based on optimal damping ratio and joint adaptive inertia parameters and damping coefficients is proposed..Finally, the correctness and effectiveness of the proposed strategy were verified by off-grid and grid-connected simulation analysis in Matlab/Simlink, and the results showed that the proposed strategy could effectively suppress system fluctuations and had good dynamic performance.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司