李争,张丽平,薛增涛,孙鹤旭,王群京.基于氢储能的双馈风力发电系统功率控制策略[J].电测与仪表,2020,57(13):76-83.
Li Zheng,Zhang Liping,Xue Zengtao,Sun Hexu,Wang Qunjing.Power control strategy of doubly-fed wind power generation system based on hydrogen energy storage[J].Electrical Measurement & Instrumentation,2020,57(13):76-83.
基于氢储能的双馈风力发电系统功率控制策略
Power control strategy of doubly-fed wind power generation system based on hydrogen energy storage
DOI:10.19753/j.issn1001-1390.2020.13.013
中文关键词:  氢储能  DC/AC  AC/DC  功率控制策略  超级电容器工作模式
英文关键词:hydrogen storage  DC/AC  AC/DC  power control strategy  supercapacitor working mode
基金项目:国家自然科学基金项目
              
作者中文名作者英文名单位
李争Li Zheng河北科技大学 电气工程学院
张丽平Zhang Liping河北科技大学 电气工程学院
薛增涛Xue Zengtao河北科技大学 电气工程学院
孙鹤旭Sun Hexu河北科技大学 电气工程学院
王群京Wang Qunjing安徽大学工业节电与电能质量控制协同创新中心,安徽合肥
摘要点击次数: 1201
中文摘要:
      本文提出一种氢储能装置集于双馈风机直流侧的并网功率控制策略。为弥补氢能动态响应慢的特点,设置控制信号的优先级:超级电容器>氢储能系统。利用信号转换模块选择工作模式,降低超级电容器的退运概率,保证电解槽恒功率运行。系统各单元通过功率控制策略和DC/DC变流器控制,平衡直流母线上的功率波动,利用DC/AC并网逆变器汇入低压交流网络。在电网冲击,负载波动,及风速出力不均的情况下,满足负载要求,实现柔性并网,同时有效解决风机弃风问题。通过仿真证明了模型及其控制策略的有效性。
英文摘要:
      This paper proposes a grid-connected power control strategy for a hydrogen storage device integrated on the DC side of a double fed induction generator. In order to compensate for the slow dynamic response of hydrogen energy, the priority of the control signal is set: supercapacitor > hydrogen storage system. The signal conversion module is used to select the working mode to reduce the probability of returning of the supercapacitor and ensure the constant power operation of the electrolyzer. Each unit of the system is controlled by the power control strategy and the DC/DC converter to balance the power fluctuations on the DC bus, and the DC/AC grid-connected inverter is used to sink into the low-voltage AC network. In the case of grid impact, load fluctuations, and uneven wind speed output, the load requirements are met, and the controllable flexible connection is realized, and the wind curtailment is effectively solved. The effectiveness of the model and its control strategy is proved by simulation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司