李晓辉,李磊,邹琪,刘小琛,杨光,朱重冶.抗直流电流互感器校验仪检定方法研究[J].电测与仪表,2019,56(22):131-138.
Li Xiaohui,Li Lei,Zou Qi,Liu Xiaochen,YangGuang,Zhu Chongye.Research on verification method of anti-DC current transformer calibrator[J].Electrical Measurement & Instrumentation,2019,56(22):131-138.
抗直流电流互感器校验仪检定方法研究
Research on verification method of anti-DC current transformer calibrator
DOI:10.19753/j.issn1001-1390.2019.022.022
中文关键词:  抗直流电流互感器  校验仪  正弦半波电流  误差检定
英文关键词:anti-DC current transformer  calibrator  sinusoidal half-wave current  error verification
基金项目:
                 
作者中文名作者英文名单位
李晓辉Li Xiaohui国网天津市电力公司电力科学研究院
李磊Li Lei国网天津市电力公司电力科学研究院
邹琪Zou Qi国网天津市电力公司电力科学研究院
刘小琛Liu Xiaochen国网天津市电力公司电力科学研究院
杨光YangGuang国网天津市电力公司电力科学研究院
朱重冶Zhu Chongye宁波三维电测设备有限公司
摘要点击次数: 1368
中文摘要:
      目前国内对于抗直流电流互感器校验仪的检定研究,除了正弦全波电流信号情况下的校验仪准确度计量可以通过整体检定方法得到传递外,对于正弦半波电流信号的测量,尚无专业校准设备可以完成。该文提出一种能满足正弦全波、全波带直流、正弦半波三种测试条件的抗直流互感器校验仪整体检定技术,分析抗直流互感器校验仪的工作原理和误差模型,特别对正弦半波工作电流情况下的校验仪误差检定和校准方法进行详细的研究,介绍该装置核心模块双路任意波程控信号源的工作机理和信号流程,并通过第三方测试设备对关键的谐波成份以及各种误差工况下的输出电流精度及稳定性进行测量和验证,对可能产生的装置不确定度进行了分析。测量结果证明,该文提出的整体检定技术达到预期效果,对于完善目前正在开展的抗直流互感器计量体系具有重要意义。
英文摘要:
      At present, there is no professional calibration equipment for the calibration of anti-DC current transformer in China, except that the accuracy measurement of the calibrator under the condition of sinusoidal full-wave current signal can be transmitted by the overall calibration method. In this paper, an integrated calibration technology of anti-DC transformer calibrator which can satisfy three test conditions of sinusoidal full-wave, full-band direct current and sinusoidal half-wave is proposed. The working principle and error model of anti-DC transformer calibrator are analyzed. In particular, the calibration method of the calibrator under sinusoidal half-wave working current is studied in detail, and the dual-channel core module of the device is introduced. The working mechanism and signal flow of the program-controlled signal source are analyzed. The key harmonic components and the output current accuracy and stability under various error conditions are measured and verified by the third-party testing equipment. The possible uncertainty of the device is analyzed. The measurement results show that the overall verification technology proposed in this paper achieves the desired results and is of great significance for improving the current measurement system of anti-DC transformers.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司