陈丹伶,欧阳森,刘丽媛.基于电能量数据的电压偏低型隐性缺供电量估算方法[J].电测与仪表,2020,57(19):86-92.
Chen Danling,Ouyang Sen,Liu Liyuan.Estimation Method of Low Voltage Type Hidden Energy not Supplied Based on Electric Energy Data[J].Electrical Measurement & Instrumentation,2020,57(19):86-92.
基于电能量数据的电压偏低型隐性缺供电量估算方法
Estimation Method of Low Voltage Type Hidden Energy not Supplied Based on Electric Energy Data
DOI:10.19753/j.issn1001-1390.2020.19.014
中文关键词:  电压质量  隐性缺供电量  静态负荷模型  用户侧供电可靠性
英文关键词:voltage  quality, hidden  energy not  supplied, static  load model, user  side power  supply reliability
基金项目:广东省自然科学基金
        
作者中文名作者英文名单位
陈丹伶Chen Danling华南理工大学 电力学院
欧阳森Ouyang Sen华南理工大学 电力学院
刘丽媛Liu Liyuan广东电网有限责任公司东莞供电局
摘要点击次数: 1476
中文摘要:
      针对电压质量影响着用户负荷的正常释放的问题,为了定量衡量电压质量对用户负荷的影响程度,本文提出了一种基于电能量数据的电压偏低型隐形缺供电量估算方法。首先,从电量的角度探讨了电压偏差与用户侧供电可靠性的关联关系,阐述了隐性缺供电量的概念和价值;其次,提出了电压偏低型隐性缺供电量的估算方法,考虑了行业用户负荷的时变性和电能质量敏感度,从时间和电压两个维度上构建了不同类型用户的分时段静态有功负荷模型;然后,利用这一负荷模型估算各类用户的隐性缺供电量和失电量比指标,用于衡量用户侧供电可靠性受电压偏低的影响程度;最后,通过算例分析,验证了本文方法的可行性和合理性。
英文摘要:
      Aiming at the problem that voltage quality affects normal release of user load, in order to quantitatively measure the influence of voltage quality, this paper proposes an estimation method of low voltage type hidden energy not supplied based on electric energy data. Firstly, the relationship between voltage deviation and user side power supply reliability is discussed from the perspective of power consumption, as well as the concept and value of hidden energy not supplied. Secondly, the hidden energy not supplied estimation method is proposed. The time-varying and power quality sensitivity of user load is considered, and the time-division static active load model of different types of user is constructed from the two dimensions of time and voltage. Then, this load model is used to estimate the hidden energy not supplied and electricity shortage ratio of various users, to measure the influence degree of low voltage on user side power supply reliability. Finally, an example proves that the method proposed in this paper shows practical application value.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司