• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
甄超,张健,季坤,王昕,邓凌峰,汪颖.电能质量治理设备运行状态识别及其治理效果评价*[J].电测与仪表,2020,57(3):60-65.
Zhen Chao,Zhang Jian,Ji Kun,Wang Xin,Deng Lingfeng,Wang Ying.Recognition of Operating State of Power Quality Compensation Equipment and Evaluation of its Effect[J].Electrical Measurement & Instrumentation,2020,57(3):60-65.
电能质量治理设备运行状态识别及其治理效果评价*
Recognition of Operating State of Power Quality Compensation Equipment and Evaluation of its Effect
DOI:10.19753/j.issn1001-1390.2020.03.010
中文关键词:  电能质量  治理设备  运行状态识别  治理效果评价  概率神经网络  模糊综合评价法
英文关键词:Power  quality, Compensation  equipment, Operation  status identification, Effect  evaluation, Probabilistic  neural network, Fuzzy  comprehensive evaluation
基金项目:国家自然科学基金项目(51807126)
                 
作者中文名作者英文名单位
甄超Zhen Chao国网安徽省电力有限公司
张健Zhang Jian国网安徽省电力有限公司
季坤Ji Kun国网安徽省电力有限公司
王昕Wang Xin深圳市中电电力技术股份有限公司
邓凌峰Deng Lingfeng四川大学电气信息学院
汪颖Wang Ying四川大学电气信息学院
摘要点击次数: 1419
中文摘要:
      针对目前电网中电能质量干扰源复杂、用户侧治理设备管理困难的现状,文中提出了基于电网侧电能质量监测数据,对用户侧治理设备进行运行状态识别以及治理效果评价的算法,实现电网公司对用户侧电能质量治理设备的非侵入式监测。首先,文章利用概率神经网络,将电压偏差、三相电压不平衡度、电压谐波总畸变率以及电压长时闪变作为网络的输入参数,对治理设备的工况进行分类,以实现治理设备的运行状态识别;其次,通过对比治理设备投入前后的电能质量评估结果,结合模糊综合评价法来完成治理设备的治理效果评价。以安徽电网某变电站的监测数据为例,分析了所提电能质量治理设备运行状态识别方法和治理效果评价方法的实用性。
英文摘要:
      In view of the complex power quality disturbance sources and the difficult management of user-side power quality compensation equipment in power grid, this paper presents an algorithm for identifying the operation status of user-side compensation equipment and evaluating its effect based on the monitoring data of power quality on power grid side. Thus, the non-intrusive monitoring of compensation equipment on the user side can be realized by using the monitoring data. Firstly, the probabilistic neural network is used to classify the working conditions of compensation equipment by taking the voltage deviation, three-phase voltage unbalance, total harmonic distortion rate and long-term voltage flicker as the input parameters, so as to realize the evaluation of the operation status of the compensation equipment. Secondly, by comparing the results of power quality evaluation before and after the operation of compensation equipment, this paper uses the fuzzy comprehensive evaluation method to achieve the effect evaluation of compensation equipment. Taking the monitoring data of a substation in Anhui Power Grid as an example, the practicability of the proposed state identification method and the effect evaluation method of the compensation equipment is analyzed.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司