• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
王渝红,凌楠,曾琦,刘程卓,石富童,刘进飞.基于换流站节点类型的直流断路器配置方法[J].电测与仪表,2020,57(18):133-140.
WANG Yuhong,LING Nan,Zeng Qi,LIU Chengzhuo,SHI Futong,LIU Jinfei.The Configuration Strategy of DC Circuit Breakers Based on Types of Converters for HVDC Grid[J].Electrical Measurement & Instrumentation,2020,57(18):133-140.
基于换流站节点类型的直流断路器配置方法
The Configuration Strategy of DC Circuit Breakers Based on Types of Converters for HVDC Grid
DOI:10.19753/j.issn1001-1390.2020.18.022
中文关键词:  高压直流电网  直流断路器  超高速隔离开关  配置策略
英文关键词:high voltage direct current grid  direct current circuit breaker  ultra fast disconnector  strategy of configuration
基金项目:国家重点研发计划资助
                 
作者中文名作者英文名单位
王渝红WANG Yuhong四川大学电气信息学院
凌楠LING Nan四川大学电气信息学院
曾琦Zeng Qi四川大学电气信息学院
刘程卓LIU Chengzhuo四川大学电气信息学院
石富童SHI Futong四川大学电气信息学院
刘进飞LIU Jinfei四川大学电气信息学院
摘要点击次数: 1111
中文摘要:
      直流电网是应对远距离大容量输电、新能源并网及消纳等问题的有效手段,然而其低阻尼特性、故障发展速度快的特点使得其隔离故障困难,研究提升直流电网故障清除能力具有重要意义。本文基于电网中直流断路器的配置要求,提出了一种基于换流站节点类型的直流断路器配置方法,其次介绍了不同故障情形时该配置方法中直流断路器的动作时序、重合闸策略,并介绍了输电线路保护判据及与换流站协调配合的措施。最后在PSCAD/EMTDC中搭建三端混合仿真模型,对本文所提配置方法与传统的配置方法下的故障进行仿真对比分析,仿真结果表明,所提配置方法能够快速隔离高压直流电网中的故障,减少停电范围,提高供电可靠性,可作为实际系统的一种可行方案。
英文摘要:
      DC grid is an effective means to deal with the problems of long-distance and large-capacity transmission, new energy integration and absorption. However, its low damping characteristics and fast fault development make it difficult to isolate faults. It is of great significance to study and improve the fault clearance capability of DC power grid. In this paper, in order to improve the fault clearance capability, a configuration strategy of direct current circuit breakers(DCB) concerning types of converters is proposed. Then, the action sequences and reclosing strategy of DCB in this configuration method under different fault conditions are introduced. The criterion of transmission line protection and the measures to coordinate with converter station are also introduced meanwhile. Finally, a three-terminal hybrid simulation model is built in PSCAD/EMTDC to simulate and analyzes the fault phenomena of the proposed configuration methods traditional configuration method, and the simulations results show that the proposed configuration can quickly isolate the faults in HVDC grid, reduce the blackout range and improve the reliability of power supply, which means the configuration can be used as feasible for practical system.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司