• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
罗立波,高阳,谷彩连,冷雪敏.基于S变换和可信度决策的谐振接地系统故障选线新方法*[J].电测与仪表,2019,56(15):84-90.
Luo Libo,Gaoyang,谷彩连,冷雪敏.A New Method of Fault Line Selection for Resonant Grounding System Based on the S-Transform and Credibility Decision[J].Electrical Measurement & Instrumentation,2019,56(15):84-90.
基于S变换和可信度决策的谐振接地系统故障选线新方法*
A New Method of Fault Line Selection for Resonant Grounding System Based on the S-Transform and Credibility Decision
DOI:10.19753/j.issn1001-1390.2019.015.013
中文关键词:  谐振接地  故障选线  S变换  可信度决策
英文关键词:resonant grounding system  fault line selection  S-transform  credibility decision
基金项目:辽宁省重点研发项目,项目号2017106018沈阳市双百重点项目,项目号Z18-5-014
           
作者中文名作者英文名单位
罗立波Luo Libo国网新疆电力有限公司昌吉供电公司
高阳Gaoyang沈阳工程学院 辽宁 沈阳
谷彩连谷彩连
冷雪敏冷雪敏
摘要点击次数: 1654
中文摘要:
      为了解决配电网谐振接地系统发生单相接地时故障选线效果欠佳的问题,本文提出了一种基于S变换和可信度决策融合的谐振接地系统故障选线新方法。论文利用S变换强大时频分析能力提取各条线路的复时频矩阵,通过可信度决策融合各条线路幅频矩阵综合相关系数和暂态能量参数两种判据,从而实现自适应地进行故障选线,提高单一选线方法的准确性和灵敏性。本文利用EMTP / ATP软件搭建了10kV配电网混合线路仿真模型,仿真结果表明该方法能够较好融合多种特征量,受中性点接地方式、故障位置、故障电阻、故障初始角、网络结构的影响较小,且判据裕度较高,在不同补偿度下均具有较高的选线准确率。
英文摘要:
      In order to solve the problem of poor fault line selection when single-phase grounding occurs in resonance grounding system of distribution network, a new method of fault line selection for resonance grounding system based on S-transform and reliability decision fusion is proposed in this paper. In this paper, the S-transformation powerful time-frequency analysis capability is used to extract the complex time-frequency matrix of each line, and the two criteria of the correlation coefficient and the transient energy parameter of each line frequency-frequency matrix are integrated by credibility decision, so that the fault line selection can be realized adaptively and the accuracy and sensitivity of the single line selection method can be improved. On the other hand, the paper use EMTP/ATP software to build a hybrid line simulation model of 10 kV distribution network. The simulation results show that this method can fuse a variety of characteristic variables well. It is less affected by neutral grounding mode, fault location, fault resistance, fault initial angle and network structure, and has higher criterion margin. It has higher efficiency in the case of multi-circuit and cable hybrid feeders.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司