• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
段惠,秦立军,赵显秋,刘梦晨.含DG的智能配电网快速自愈技术研究[J].电测与仪表,2021,58(7):67-73.
DUAN HUI,Qin Lijun,Zhao Xianqiu,Liu Mengchen.Research on Rapid Self-healing Technology of Smart Distribution Network with DG[J].Electrical Measurement & Instrumentation,2021,58(7):67-73.
含DG的智能配电网快速自愈技术研究
Research on Rapid Self-healing Technology of Smart Distribution Network with DG
DOI:10.19753/j.issn1001-1390.2021.07.009
中文关键词:  智能配电网 分布式电源 无通道保护 快速自愈 高速开关
英文关键词:Smart Distribution Network , Distributed Generation,No Channel Protection , Fast Self-Healing, High Speed Switch
基金项目:
           
作者中文名作者英文名单位
段惠DUAN HUI华北电力大学
秦立军Qin Lijun华北电力大学
赵显秋Zhao Xianqiu华北电力大学
刘梦晨Liu Mengchen华北电力大学
摘要点击次数: 1405
中文摘要:
      由于我国城镇配电网在建设之初并没有考虑到智能电网导致目前难以配置通信通道,且分布式电源接入配电网使传统的三段式过流保护难以适应拓扑的变化而失去判据。为解决这一问题,本文首先分析了正序分量控制策略下逆变型分布式电源的等值数学模型,然后结合对称分量法以相间短路为例分析了分布式电源对故障电流的影响。最后提出了一种适用于含分布式电源的配电线路的无通道保护快速自愈方案,按区域划分断路器分别进行整定,并结合涡流斥力真空高速开关使故障线路快速切除。该方案不依靠通信通道,节省了建设维护通信通道的成本,配电线路可在0.3s内实现自愈,符合中压配电网继电保护整定原则的要求。通过PSCAD/EMTDC仿真验证了所提方法的正确性。
英文摘要:
      Since China""s urban distribution network did not consider the smart grid at the beginning of construction, it is difficult to configure the communication channel at present, and the distributed power supply access distribution network makes the traditional three-stage overcurrent protection difficult to adapt to the topology change and loses the criterion. . In order to solve this problem, the paper firstly analyzes the equivalent mathematical model of the inverter-type distributed power supply under the positive sequence component control strategy, and then analyzes the influence of the distributed power source on the fault current by using the symmetrical component method as an example. Finally, a non-channel protection rapid self-healing scheme suitable for distribution lines with distributed power supply is proposed. The circuit breakers are divided according to the area, and the fault line is quickly cut off by combining the eddy current repulsive vacuum high-speed switch. The solution does not rely on the communication channel, which saves the cost of constructing and maintaining the communication channel. The distribution line can achieve self-healing within 0.3s, which meets the requirements of the relay protection setting principle of the medium voltage distribution network. The correctness of the proposed method is verified by PSCAD/EMTDC fault simulation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司