• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
张海生,彭玲艳,徐昊亮,徐慧慧.考虑不对称时延的线路电流差动保护拒动和误动概率分析[J].电测与仪表,2021,58(2):40-46.
ZHANG Haisheng,PENG Lingyan,XU Haoliang,XU Huihui.Probability analysis of disoperation and misoperation of line current differential protection considering asymmetric delay[J].Electrical Measurement & Instrumentation,2021,58(2):40-46.
考虑不对称时延的线路电流差动保护拒动和误动概率分析
Probability analysis of disoperation and misoperation of line current differential protection considering asymmetric delay
DOI:10.19753/j.issn1001-1390.2021.02.007
中文关键词:  线路电流差动保护  不对称时延  拒动概率  误动概率
英文关键词:line current differential protection, asymmetric delay, disoperation probability, misoperation probability
基金项目:国网甘肃省电力公司委托开发项目《电力通信网运行质量及业务风险评估技术研究》(合同编号:SGGSJY00PSJS1800140)
           
作者中文名作者英文名单位
张海生ZHANG Haisheng国网甘肃省电力公司经济技术研究院
彭玲艳PENG Lingyan华北电力大学(保定)
徐昊亮XU Haoliang国网甘肃省电力公司经济技术研究院
徐慧慧XU Huihui国网甘肃省电力公司经济技术研究院
摘要点击次数: 1504
中文摘要:
      通道时延不对称会影响线路电流差动保护的时间同步精度,并降低保护动作的可靠性。有必要对拒动和误动的影响机理进行深入研究,以提高线路保护的整体可靠性。首先,根据线路电流差动保护的基本原理和时间同步方式,分析了通道不对称时延导致保护拒动和误动的原因;然后,给出了通道不对称时延诱导的拒动和误动概率模型,并设计了相应算法;最后,以5种线路保护场景作为算例,验证了算法的可行性和有效性,定量研究了在通道不对称时延概率分布函数相同条件下,拒动和误动概率的不同特征。研究成果对继电保护通道的优化配置和保护策略选择具有参考价值。
英文摘要:
      The asymmetry of channel delay will affect the time synchronization accuracy of line current differential protection and reduce the reliability of protection action. It is necessary to conduct an in-depth study on the mechanism of the impact of disoperation and misoperation to improve the overall reliability of line protection. Firstly, according to the basic principle of line current differential protection and time synchronization mode, the reasons of protection disoperation and misoperation caused by asymmetric channel delay were analyzed. Then, the probability models of disoperation and misoperation induced by asymmetric channel delay were given, and the corresponding algorithms were designed. Finally, five scenarios of line protection were taken as examples to verify the feasibility and effectiveness of the algorithm. The different characteristics of disopetation probability and misoperation probability under the same asymmetric channel delay probability distribution function were studied quantitatively. The results have reference value for the optimal configuration and the selection of protection strategies of relay protection channels.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司