王劭菁,王丰华,曾全昊,周东旭.基于电磁层析成像技术的接地网导体异常检测[J].电测与仪表,2021,58(6):140-147.
Wang Shao-jing,Wang Feng-hua,Zeng Quan-hao,Zhou Dong-xu.Abnormal Detection of Grounding Grid Conductor Based on EMT Techonology[J].Electrical Measurement & Instrumentation,2021,58(6):140-147.
基于电磁层析成像技术的接地网导体异常检测
Abnormal Detection of Grounding Grid Conductor Based on EMT Techonology
DOI:10.19753/j.issn1001-1390.2021.06.019
中文关键词:  接地网  电磁层析成像技术  感应电压  Landweber 迭代算法  图像相关系数
英文关键词:Grounding  grid, Electromagnetic  Tomography technology, induced  voltage, Landweber  iteration algorithm, image  correlation coefficient
基金项目:
           
作者中文名作者英文名单位
王劭菁Wang Shao-jing国网上海市电力公司电力科学研究院
王丰华Wang Feng-hua上海交通大学电力传输与功率变换控制教育部重点实验室
曾全昊Zeng Quan-hao上海交通大学电力传输与功率变换控制教育部重点实验室
周东旭Zhou Dong-xu上海交通大学电力传输与功率变换控制教育部重点实验室
摘要点击次数: 1565
中文摘要:
      接地网是维护系统安全、保障运行人员及设备安全的重要环节,对其异常状态的有效检测直接关系到电力系统的安全稳定运行。本文研究了基于电磁层析成像(Electromagnetic Tomography, EMT)技术的接地网导体异常状态检测方法,应用改进Landweber 迭代算法基于EMT技术测试系统的感应电压测量结果获取了接地网导体的重建图像,定义了图像相关系数对接地网导体的异常状态进行检测。对某35kV接地网正常与腐蚀、断裂等典型故障下的分析结果表明,将EMT计算引入接地网导体的异常检测具有一定的可行性,且具有非接触、对接地网导体状态变化敏感等优势,所定义的图像相关系数指标能有效识别接地网导体的异常状态。研究结果可为接地网运行状态的准确评估提供重要依据。
英文摘要:
      Grounding grid is the important parts in power system to maintain the security of power system, electrical staff and equipment. How to effectively detect the abnormal condition of grounding grid is closely related to the secure and stale operation of power system. The Electromagnetic Tomography (EMT) technology is introduced in the paper to detect the abnormal condition of grounding grid conductors. Based to the result of induction voltage resulted from the EMT technology test system, the improved Landweber iteration algorithm is applied to obtain the reconstruction image of grounding grid conductors. The image correlation coefficient is defined to detect the abnormal condition of grounding grid conductors. The results of a 35kV substation grounding grid conductors under normal and typical faults including corrosion and fracture have shown that it is feasible to detect the abnormal condition of grounding grid conductors by the EMT technology with the advantage of non-contact and high sensitivity to the condition of grounding grid conductors. The defined image correlation coefficient is capable of recognize the abnormal condition of grounding grid conductors. The results could provide the important reference for the condition assessment of grounding grid.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司