向国杰,曾祥君,喻锟,梁洪湘,赵子墨.基于相位差的不对称配电网接地故障选相方法[J].电测与仪表,2020,57(22):70-76.
Xiang Guojie,Zeng Xiangjun,Yu Kun,Liang Hongxiang,Zhao Zimo.Phase selection method for grounding faults of asymmetric distribution network based on phase difference[J].Electrical Measurement & Instrumentation,2020,57(22):70-76.
基于相位差的不对称配电网接地故障选相方法
Phase selection method for grounding faults of asymmetric distribution network based on phase difference
DOI:DOI: 10.19753/j.issn1001-1390.2020.22.010
中文关键词:  不对称配电网  接地故障  选相  相位差
英文关键词:asymmetric distribution network, ground fault, phase selection, phase difference
基金项目:国家自然科学基金项目(51737002)
              
作者中文名作者英文名单位
向国杰Xiang Guojie长沙理工大学电气与信息工程学院
曾祥君Zeng Xiangjun长沙理工大学电气与信息工程学院
喻锟Yu Kun长沙理工大学电气与信息工程学院
梁洪湘Liang Hongxiang长沙理工大学电气与信息工程学院
赵子墨Zhao Zimo长沙理工大学电气与信息工程学院
摘要点击次数: 1320
中文摘要:
      在配电网中性点不接地及经消弧线圈接地系统中,针对传统接地故障选相方法未考虑泄漏电阻及三相不对称情况导致过渡电阻较高时选相错误的问题,论文提出了基于相位差的不对称配电网接地故障选相方法,考虑线路泄漏电阻及三相不对称参数,分析了故障相电压和故障前后中性点电压变化量的相位差与消弧线圈补偿状态及线路参数的内在联系,得出了接地故障选相判据,最后提出了配电网接地故障选相方法实现方案。在PSCAD/EMTDC仿真环境中搭建配电网接地故障模型,仿真结果表明在不同过渡电阻及消弧线圈不同补偿状态下判据均适用,验证了所提方法的可行性。
英文摘要:
      In the neutral point ungrounded system of the distribution network and the grounding system through the arc suppression coil, the traditional ground fault phase selection method does not consider leakage resistance and three-phase asymmetry. The phase selection error is caused when the transition resistance is high. Phase selection method based on phase difference for grounding faults in asymmetric distribution networks is proposed in the paper. Line leakage resistance and three-phase asymmetry parameters are considered in the paper. The intrinsic relationship between the phase difference between the fault phase voltage and the neutral point voltage change before and after the fault and the arc suppression coil compensation state and line parameters are analyzed. The ground fault selection criterion is obtained. Finally, the implementation scheme of phase selection method for grounding fault of distribution network is proposed. The grounding fault model of the distribution network is built in the PSCAD/EMTDC simulation environment. The simulation results show that the criterion is always applicable under different transition resistances and different arc suppression coil compensation states. The feasibility of the proposed method is verified.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司