甘艳,杜志叶,周文峰,张力,邹建明.基于覆冰拉力监测系统的耐张塔线路等值冰厚计算模型[J].电测与仪表,2021,58(5):39-45.
Gan Yan,Du Zhiye,Zhou Wenfeng,Zhang Li,Zou Jianming.Equivalent Ice Thickness Calculation Model of Strain Tower Based on Iced Tensile Monitoring System[J].Electrical Measurement & Instrumentation,2021,58(5):39-45.
基于覆冰拉力监测系统的耐张塔线路等值冰厚计算模型
Equivalent Ice Thickness Calculation Model of Strain Tower Based on Iced Tensile Monitoring System
DOI:10.19753/j.issn1001-1390.2021.05.006
中文关键词:  输电线路  覆冰  耐张塔  等值冰厚  拉力
英文关键词:transmission line, Ice coating, strain tower, equivalent ice thickness, traction
基金项目:国家电网华中分部科技项目(SGHZ0000AJQT1800181)
              
作者中文名作者英文名单位
甘艳Gan Yan国家电网华中分部
杜志叶Du Zhiye武汉大学电气与自动化学院
周文峰Zhou Wenfeng武汉大学电气与自动化学院
张力Zhang Li武汉大学电气与自动化学院
邹建明Zou Jianming国家电网华中分部
摘要点击次数: 2046
中文摘要:
      输电线路覆冰严重影响电网的安全稳定运行,准确监测线路覆冰情况具有重要的工程意义和应用价值。为了精准判断线路覆冰厚度,提出一种基于覆冰拉力监测系统的复合荷载作用下耐张塔线路等值冰厚计算模型,以在线监测终端监测拉力和角度为输入参量,计及耐张绝缘子串非均布荷载和风荷载影响,并修正重力方向荷载对计算模型加以改进。与雪峰山自然观冰站试验数据和南方电网重覆冰区段监测终端运行数据对比,验证了该计算模型的准确性。结合工程实际应用,对判断耐张塔线路覆冰情况具有一定的指导作用。
英文摘要:
      The ice coating on the transmission line seriously affects the safe and stable operation of the power grid. It is of great engineering significance and application value to accurately monitor the ice coverage of the line. In order to accurately judge the icing thickness of transmission lines, a calculation model of equivalent icing thickness of strain tower lines under combined loads based on the icing tension monitoring system is proposed, in which the tension and angle of strain tower lines are monitored on-line as input parameters, the effects of non-uniform distributed loads and wind loads of strain insulator strings are taken into account, and the calculation model is improved by modifying gravity direction loads. Compared with the test data of Xuefengshan Natural View Ice Station and the operation data of monitoring terminal in the overlying ice section of the South China Power Grid, the accuracy of the calculation model is verified. Combining with the engineering practice, this paper has a certain guiding role in judging the icing situation of the strain tower.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司