江友华,屈靖洁,曹以龙,汪源.考虑风电-负荷及综合需求响应不确定性的能量枢纽双层优化运行及配置方法[J].电测与仪表,2022,59(3):117-124,162.
jiangyouhua,qujingjie,caoyilong,wangyuan.A two-layer optimal operation and configuration method for energy hub considering uncertainty of wind power - load and comprehensive demand response[J].Electrical Measurement & Instrumentation,2022,59(3):117-124,162.
考虑风电-负荷及综合需求响应不确定性的能量枢纽双层优化运行及配置方法
A two-layer optimal operation and configuration method for energy hub considering uncertainty of wind power - load and comprehensive demand response
DOI:10.19753/j.issn1001-1390.2022.03.015
中文关键词:  多能源系统  能量枢纽  综合需求响应  不确定性场景  优化配置  
英文关键词:
基金项目:
           
作者中文名作者英文名单位
江友华jiangyouhua上海电力大学
屈靖洁qujingjie上海电力大学
曹以龙caoyilong上海电力大学
汪源wangyuan国网浙江淳安县供电有限公司
摘要点击次数: 1763
中文摘要:
      现有研究在关注多能互补系统中源荷双侧不确定性问题时忽略了用户侧综合需求响应(IDR)不确定性的影响,为此,本文以能量枢纽(EH)为研究对象,综合考虑可再生能源发电侧、用电侧以及用户侧电/热综合需求响应三方面不确定性,提出一种双层能量枢纽规划配置模型。首先结合非参数密度估计与Copula理论对传统源荷双侧不确定性概率模型进行改进,同时基于基线负荷和负荷弹性系数双重不确定性,提出电/热综合需求响应量计算方法;在此基础上,以系统年综合运行费用最小为目标分层求解能量枢纽设备配置与能量分配情况。算例表明,配置计算中计及IDR有助于平缓系统净负荷曲线,减小用户用能及间歇性电源出力不确定性对系统配置结果的影响,使系统经济、环保运行。
英文摘要:
      The existing studies ignore the influence of the uncertainty of integrated demand response (IDR) on the system configuration. Therefore, taking energy hub (EH) as the research object, a two-layer energy hub planning and configuration model is proposed with the uncertainty of wind power output, power load and integrated demand response quantity of electricity/heat comprehensively considered. Firstly, based on kernel density estimation and Copula theory, the joint probability distribution of wind power output-electricity baseline load is established, and typical daily scenarios are generated. At the same time, based on the double uncertainty of baseline load and load elasticity coefficient, a method for calculating the stochastic response quantity of integrated demand for electricity and heat is proposed. Then a mixed integer nonlinear programming model is established with the goal of minimizing the annual operating cost of the system. The example shows that taking IDR into account in the configuration calculation can help to smooth the net load curve of the system, reduce the influence of user energy and intermittent power supply output uncertainty on the system configuration result, and thus improve the system economy.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司