• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
彭刚,钟振鑫,肖瑞超,李海锋.基于零序电流-电压微分特性的小电阻接地系统接地保护原理[J].电测与仪表,2021,58(7):143-149.
Peng Gang,Zhong Zhenxin,Xiao Ruichao,Li Haifeng.Grounding faults protection in low-resistance grounded systems based on zero-sequence current-voltage differential characteristics[J].Electrical Measurement & Instrumentation,2021,58(7):143-149.
基于零序电流-电压微分特性的小电阻接地系统接地保护原理
Grounding faults protection in low-resistance grounded systems based on zero-sequence current-voltage differential characteristics
DOI:10.19753/j.issn1001-1390.2021.07.020
中文关键词:  小电阻接地系统  高阻接地故障  零序保护  波形相似度  PSCAD
英文关键词:Low-resistance grounding system  high impedance ground fault  zero-sequence protection  waveform similarity  PSCAD
基金项目:
           
作者中文名作者英文名单位
彭刚Peng Gang广东电网有限责任公司梅州供电局
钟振鑫Zhong Zhenxin广东电网有限责任公司惠州供电局
肖瑞超Xiao Ruichao华南理工大学电力学院
李海锋Li Haifeng华南理工大学电力学院
摘要点击次数: 1892
中文摘要:
      中性点经小电阻接地的系统适用于电缆居多的配电网,然而由于配网馈线所处环境复杂,造成了现有的基于零序电流阶段式的保护方案无法满足单相高阻接地故障快速、灵敏地检测需求。针对此现象,文中通过分析故障线路和非故障线路零序电流-零序电压的关系,寻求两者不同的故障特征,由此提出一种基于线路零序电流与母线零序电压微分值波形相似度的保护算法。本保护算法通过对线路的零序电流和零序电压进行采样,并根据线路零序电流与母线零序电压微分值的波形相似度来判断线路是否发生单相接地故障,可大大提高单相高阻接地故障保护的灵敏度。最后通过PSCAD仿真测试验证了该算法的有效性。
英文摘要:
      The neutral point through the low-resistance grounding system is applicable to the distribution network with majority of cables. However, due to the complicated environment of the distribution feeder, single-phase high-impedance ground faults cannot be detected rapidly and sensitively by existing zero-sequence overcurrent protection. To solve this problem, this paper analyzes the relationship between the zero-sequence current and the zero-sequence voltage of faulty line and healthy line, and seeks different fault characteristics between them. A protection algorithm based on the waveform similarity between the line zero-sequence current and the bus zero-sequence voltage differential is proposed. Sampling the zero-sequence current and the zero-sequence voltage of the line, the proposed method judge whether a single-phase ground fault occurs on the line by comparing the waveform similarity between the line zero-sequence current and the bus zero-sequence voltage differential value, which can greatly improve the sensitivity of ground fault protection. Finally, the effectiveness of the algorithm is verified by PSCAD simulation.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司