刘 聪,李立生,刘 洋,王永亮.基于准PR控制的锂电池储能并网系统功率控制[J].电测与仪表,2021,58(8):172-178.
LIU Cong,LI Lisheng,LIU Yang,WANG Yongliang.Power control of lithium battery energy storage grid-connected system based on quasi-PR control[J].Electrical Measurement & Instrumentation,2021,58(8):172-178.
基于准PR控制的锂电池储能并网系统功率控制
Power control of lithium battery energy storage grid-connected system based on quasi-PR control
DOI:10.19753/j.issn1001-1390.2021.08.024
中文关键词:  锂电池  直接功率控制  准PR控制器  αβ坐标系  参数整定
英文关键词:lithium  battery, direct  power control, quasi-PR  controller, αβ coordinate  system, parameter  design
基金项目:国网山东省电力公司科技项目资助(520626190049)
           
作者中文名作者英文名单位
刘 聪LIU Cong山东理工大学 电气与电子工程学院
李立生LI Lisheng国网山东省电力公司 电力科学研究院
刘 洋LIU Yang国网山东省电力公司 电力科学研究院
王永亮WANG Yongliang山东理工大学 电气与电子工程学院
摘要点击次数: 1768
中文摘要:
      传统PQ控制下的锂电池储能系统需引入直流解耦分量,导致并网电能质量动态功率补偿性能受到影响,且控制结构较复杂。本文提出准比例谐振(PR)控制的锂电池储能并网系统的直接功率控制策略。该策略无需内环解耦,省去了锁相环的使用,简化了传统PQ控制的结构,彻底避免了控制系统内环直流解耦分量对控制系统的影响,实现了对交流量的无静差跟踪,使并网电能质量和功率动态响应速度有一定的提高。此外,提出一种全新的参数整定方法对准PR控制器的参数进行设计,以保证控制系统的稳定性和可靠性。最后,构建改进后的的锂电池储能并网系统仿真模型,验证所设计并网系统的可行性和有效性。
英文摘要:
      The lithium battery energy storage system by the traditional PQ control is affected by the DC decoupling component, resulting in power quality and dynamic power compensation performance be affected, and more complex control structure. This paper adopts the grid-connected power control strategy of lithium battery energy storage based on quasi-PR controller. This strategy simplifies the traditional PQ control algorithm and eliminates the need to introduce decoupling components into the control inner loop, eliminating the use of PLL and avoiding the influence of the DC decoupling component of the control system, achieves the zero stady-state error tracking of AC, improves the power quality and response speed of grid-connected. A new tuning method is proposed to design the quasi PR controller to ensure the stability and reliability of the control system.Finally, the improved lithium battery energy storage grid-connected system simulation model is constructed to verify the feasibility and effectiveness of the designed controller.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司