• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
林翔,方健,王红斌,张行,方敏,李盛楠.基于重要参量和参数修正的配电网设备故障率计算方法[J].电测与仪表,2022,59(2):141-147.
Lin Xiang,Fang Jian,Wang Hongbin,Zhang Hang,Fang Min,Li Shengnan.Calculation method of equipment failure rate in distribution network based on important parameters and parameter correction[J].Electrical Measurement & Instrumentation,2022,59(2):141-147.
基于重要参量和参数修正的配电网设备故障率计算方法
Calculation method of equipment failure rate in distribution network based on important parameters and parameter correction
DOI:10.19753/j.issn1001-1390.2022.02.020
中文关键词:  渐变性因素  突发性因素  实时故障率  配电网  参数修正
英文关键词:gradual factor, sudden factor, real-time failure rate, distribution network, parameter correction
基金项目:中国南方电网有限责任公司科技项目“配电网重复多发性停电防治能力提升关键技术研究及应用”(GZJKJXM20170012)
                 
作者中文名作者英文名单位
林翔Lin Xiang广州供电局有限公司
方健Fang Jian广州供电局有限公司
王红斌Wang Hongbin广州供电局有限公司
张行Zhang Hang广州供电局有限公司
方敏Fang Min广州供电局有限公司
李盛楠Li Shengnan广州供电局有限公司
摘要点击次数: 1547
中文摘要:
      针对现有研究中,利用配电设备的平均故障率进行建模修正的方法忽略了一些因素的影响,以及基于健康指数计算设备故障率的模型研究还不准确等问题,提出了基于重要参量输入和故障率参数修正相结合的方法。将影响配电设备故障率的因素分成渐变性因素和突发性因素;筛选出各故障模式对应的重要监测参量,采用基于重要参量输入的方法计算渐变性因素联合作用下的故障率;使用故障率参数修正模型逐一计算主要突发性因素对故障率的影响;通过实例验证了方法的有效性。该方法结合在线监测实时数据和环境的影响计算得到的设备故障率,能够准确反映同一类型设备不同个体之间的差异化实时状态。
英文摘要:
      In view of the existing research, the method of modeling and correction using the average failure rate of distribution equipment ignores the influence of some factors, and the model research based on health index to calculate the failure rate of distribution equipment is not accurate, a method based on important parameter input and fault rate parameter correction is proposed in this paper. Firstly, the factors affecting the failure rate of distribution equipment are divided into gradual factors and sudden factors. Then, the important monitoring parameters corresponding to each fault mode are selected and the failure rate under the combined action of gradual factors is calculated by using the method based on the input of important parameters. Then, the failure rate parameter correction model is adopted to calculate the impact of major sudden factors on the failure rate one by one. Finally, the effectiveness of the proposed method is verified by an example. This method can accurately reflect the differential real-time state of different individuals of the same type of equipment by combining the real-time data of online monitoring and the influence of environment to calculate the failure rate of device.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司