李巍巍,白欢,吴惟庆,杨兰,朱轲,张睿,赵莉华.基于振荡波局部放电检测的电力电缆绝缘老化状态评价与故障定位[J].电测与仪表,2021,58(9):147-151.
Li Weiwei,Bai Huan,Wu Weiqing,Yang Lan,Zhu Ke,Zhang Rui,Zhao Lihua.Evaluation and fault location of power cable insulation aging based on oscillation-wave partial discharge detection[J].Electrical Measurement & Instrumentation,2021,58(9):147-151.
基于振荡波局部放电检测的电力电缆绝缘老化状态评价与故障定位
Evaluation and fault location of power cable insulation aging based on oscillation-wave partial discharge detection
DOI:10.19753/j.issn1001-1390.2021.09.022
中文关键词:  振荡波  交联聚乙烯  电力电缆  在线监测  局部放电
英文关键词:Oscillating-wave, Cross-linked polyethylene, Power-cable, On-line monitoring, Partial discharge
基金项目:
                    
作者中文名作者英文名单位
李巍巍Li Weiwei国网四川省电力公司电力科学研究院
白欢Bai Huan国网四川省电力公司电力科学研究院
吴惟庆Wu Weiqing四川大学 电气工程学院
杨兰Yang Lan四川大学 电气工程学院
朱轲Zhu Ke国网四川省电力公司电力科学研究院
张睿Zhang Rui国网四川省电力公司电力科学研究院
赵莉华Zhao Lihua四川大学 电气工程学院
摘要点击次数: 1366
中文摘要:
      随着我国社会发展进步,电缆线路的铺设速度愈发加快。交联聚乙烯电缆凭借其优良的运行性能,在国内广泛铺设,但囿于复杂的运行环境,电缆常因此受到不同程度的绝缘老化。目前,在高压交联电缆线路现场试验和状态检测中,阻尼振荡波电压下的局部放电实验还未有重大突破,缺乏相关的实验数据。本论文介绍了振荡波局部放电实验的原理及其实验装置,并对通过对比分析三条绝缘老化程度差异明显、在电缆接头与终端分别出现绝缘缺陷的电力电缆,得到了绝缘老化程度与电缆局部放电参数(放电起始电压、放电电量等)之间的相对关系。凭借局部放电定位的手段,进行了电缆绝缘老化故障的位置分析,并证明了阻尼振荡波电压下的局部放电实验的优良性与适用性。
英文摘要:
      With the progress of the social development of our country, the laying speed of the cable line is increasing. The cross-linked polyethylene cable is widely laid in the country by virtue of its excellent operating performance, but in a complex operating environment, the cable is often subjected to different degree of insulation aging. At present, in the field test and state detection of the high-voltage cross-link cable, there is no significant breakthrough in the partial discharge experiment under the voltage of the ringing wave, and the relevant experimental data is not available. In this paper, the principle of partial discharge experiment of oscillation wave and its experimental device are introduced, and the difference of three insulation aging degree is obvious through contrast analysis. The relative relationship between the insulation aging degree and the partial discharge parameters (discharge initial voltage, discharge electricity, etc.) of the cable is obtained. By means of partial discharge location, the location analysis of cable insulation aging fault is carried out, and the advantages and applicability of partial discharge experiment under damping oscillatory wave voltage are proved.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司