陈建平,桑林卫,吴在军,汤拓.基于幅相关系的有源配电网多端差动保护方案[J].电测与仪表,2021,58(9):71-77.
Chen Jianping,Sang Linwei,Wu Zaijun,Tang Tuo.Multi-terminal differential protection scheme for active distribution network based on amplitude and phase relationship[J].Electrical Measurement & Instrumentation,2021,58(9):71-77.
基于幅相关系的有源配电网多端差动保护方案
Multi-terminal differential protection scheme for active distribution network based on amplitude and phase relationship
DOI:10.19753/j.issn1001-1390.2021.09.011
中文关键词:  多端电流  差动保护  有源配电网  启动判据
英文关键词:Multi-terminal current, differential protection, active distribution network, start criterion
基金项目:
           
作者中文名作者英文名单位
陈建平Chen Jianping浙江双成电气有限公司
桑林卫Sang Linwei东南大学
吴在军Wu Zaijun东南大学
汤拓Tang Tuo东南大学
摘要点击次数: 1775
中文摘要:
      分布电源的大量接入使配电网从传统单向潮流的辐射状网络逐步转变为双向潮流的多端电源供电的配电网,出现了以T型接线为代表的多段线路。文章从多种类型分布式电源的故障特性入手,分析短路故障下有源配电网的多端电流的幅相关系,提出基于多端电流幅相关系的差动保护方案。保护方案包括启动判据和复合动作判据,启动判据兼具区分部分区外故障的作用,动作判据为两个独立判据的逻辑与,以保证可靠动作和避免误动。此外,文章讨论基于光纤通道通讯的配电网多端信息同步技术,用以实现多端信息同步传输。PSCAD/EMTDC的仿真结果表明所提方案的可靠性和速动性。
英文摘要:
      The large amount of access to the distributed power supply has gradually transformed the distribution network from the traditional unidirectional tidal radial network to the two-way tidal multi-terminal power supply distribution network, and a multi-segment line represented by T-type wiring has appeared. Based on the fault characteristics of various types of distributed power supplies, this paper analyzes the amplitude-phase relationship of multi-terminal currents in active distribution networks under short-circuit faults, and proposes a differential protection scheme based on multi-terminal current amplitude-phase relationship. The protection scheme includes the initiation criterion and the composite action criterion. The initiation criterion has the function of distinguishing the faults outside the zone. The action criterion is the logical sum of two independent criteria to ensure reliable action and avoid mis-operation. In addition, the article discusses multi-end information synchronization technology based on Fibre Channel communication for distribution network to realize multi-terminal information synchronization transmission. The simulation results of PSCAD/EMTDC show the reliability and quickness of the proposed scheme.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司