• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
梁洪湘,曾祥君,喻锟,向国杰,熊一帆.基于有源逆变分相注入的电压消弧与位移电压抑制方法[J].电测与仪表,2022,59(1):51-60.
Liang Hongxiang,Zeng Xiangjun,Yu Kun,Xiang Guojie,Xiong Yifan.Voltage arc suppression and displacement voltage suppression method based on active inverter separate phase injection[J].Electrical Measurement & Instrumentation,2022,59(1):51-60.
基于有源逆变分相注入的电压消弧与位移电压抑制方法
Voltage arc suppression and displacement voltage suppression method based on active inverter separate phase injection
DOI:10.19753/j.issn1001-1390.2022.01.007
中文关键词:  配电网  单相接地故障  电压消弧  三相不平衡
英文关键词:distribution  network, single-phase  grounding fault, voltage  arc suppression, three-phase  unbalance
基金项目:
              
作者中文名作者英文名单位
梁洪湘Liang Hongxiang长沙理工大学 电气与信息工程学院
曾祥君Zeng Xiangjun长沙理工大学 电气与信息工程学院
喻锟Yu Kun长沙理工大学 电气与信息工程学院
向国杰Xiang Guojie长沙理工大学 电气与信息工程学院
熊一帆Xiong Yifan长沙理工大学 电气与信息工程学院
摘要点击次数: 1058
中文摘要:
      针对配电网发生单相接地故障时极易产生电弧以及在非故障情况下由于三相对地参数不相同而导致的三相电压不对称问题,本文提出一种基于有源逆变分相注入的电压消弧与位移电压抑制方法。在三相线路首端分别挂接有源逆变,通过脉宽调制信号控制有源逆变电路的输出电流。当配电网出现单相接地故障时,有源逆变向系统分相注入零序电流,通过零序回路调节故障相电压,将故障相电压钳制为0V,破坏电弧重燃条件。在非故障情况下,当配电网对地参数不对称而导致三相电压不对称时,有源逆变向系统分相注入零序电流,通过零序回路调节中性点电压,钳制中性点电压为0V,实现中性点位移电压抑制。仿真结果表明,该方法可有效破坏电弧重新燃弧条件以及抑制中性点位移电压。
英文摘要:
      Aiming at the problem of arc generation when single-phase grounding fault occurs in distribution network and three-phase voltage asymmetry caused by different parameters of three-phase to ground in non-fault condition, a method of voltage arc suppression and displacement voltage suppression based on active inverters phased injection is proposed in this paper. Active inverter is connected to the first end of the three-phase line, and the output current of the active inverter circuit is controlled by the pulse width modulation signal. When a single-phase ground fault occurs in the distribution network, the active inverter split phase injects zero-sequence current into the system, adjusts the fault phase voltage through the zero-sequence loop, clamps the fault point voltage to 0V, and destroys the arc re-ignition condition. In the case of non-fault, when the three-phase voltage is asymmetrical due to the asymmetrical parameters of the distribution network to the ground, the active inverters inject zero-sequence current into the system separately, adjust the neutral-point voltage through the zero-sequence circuit, clamp the neutral-point voltage to 0 V, and realize the neutral-point displacement voltage suppression. The simulation results show that the method can effectively destroy the arc reburning conditions and suppress the neutral point displacement voltage.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司