康鹏,郭伟,黄伟钢,乐健,毛涛.区域电网电能质量问题及治理关键技术综述[J].电测与仪表,2020,57(24):1-12.
Kang Peng,Guo Wei,Huang Weigang,Le Jian,Mao Tao.Review of the Power Quality Problem and Key Improvement Technology of Regional Power Grid[J].Electrical Measurement & Instrumentation,2020,57(24):1-12.
区域电网电能质量问题及治理关键技术综述
Review of the Power Quality Problem and Key Improvement Technology of Regional Power Grid
DOI:10.19753/j.issn1001-1390.2020.24.001
中文关键词:  区域电网  谐波污染  三相不平衡  低电压问题  电能质量治理
英文关键词:Regional power grid  Harmonic pollution  Three-phase unbalance  Low-voltage problem  Power quality governance
基金项目:国家自然科学基金资助项目:51877154
              
作者中文名作者英文名单位
康鹏Kang Peng国网节能服务有限公司
郭伟Guo Wei国网节能服务有限公司
黄伟钢Huang Weigang国网节能服务有限公司
乐健Le Jian武汉大学 电气与自动化学院
毛涛Mao Tao武汉东湖学院 机电工程学院
摘要点击次数: 1979
中文摘要:
      本文对区域电网影响程度最大,影响范围最广的稳态电能质量问题的现状、分析方法和治理技术开展了综述。分析了区域电网中典型的谐波源及其谐波特征,简述了谐波对区域电网的影响,分主动和被动两类介绍了主要的谐波治理措施。分析了区域电网三相不平衡问题的来源、现状及危害,重点介绍了相关标准及不平衡度计算方法,介绍了解决三相不平衡问题的运行措施和治理设备。分析了区域电网低电压问题的现状、产生机理及危害,分析了低电压监测存在的问题并总结了相应的治理技术。最后指出了治理区域电网稳态电能质量问题的关键。
英文摘要:
      In this paper, the status quo, analysis methods and treatment technologies of steady-state power quality problems with the greatest impact and the widest impact on regional power grids are reviewed. The typical harmonic sources and their harmonic characteristics in the regional power grid are analyzed. The influence of harmonics on the regional power grid is briefly described. The main harmonic control measures are introduced in two categories: active and passive. The source, current situation and harm of three-phase unbalance in regional power grid are analyzed. The relevant standards and calculation methods of unbalance degree are emphatically introduced. The operation measures and treatment equipment to solve the three-phase unbalance problem are introduced. The current situation, mechanism and harm of low voltage problem in regional power grid are analyzed. The existing problems of low voltage monitoring are analyzed and the corresponding treatment technologies are summarized. Finally, the key to control the steady-state power quality of regional power grid is pointed out.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司