刘宏,王伟.基于射频信号特征的高压开关特性非接触式检测研究[J].电测与仪表,2022,59(6):138-144.
liuhong,wangwei.Research on non-contact detection of high voltage switch characteristics based on radio frequency signal characteristics[J].Electrical Measurement & Instrumentation,2022,59(6):138-144.
基于射频信号特征的高压开关特性非接触式检测研究
Research on non-contact detection of high voltage switch characteristics based on radio frequency signal characteristics
DOI:DOI: 10.19753/j.issn1001-1390.2022.06.019
中文关键词:  射频法  信号特征  高压开关  非接触式检测
英文关键词:radio frequency method, signal characteristics, high-voltage switch, non-contact detection
基金项目:国网山西省电力公司科技项目
     
作者中文名作者英文名单位
刘宏liuhong国网山西省电力公司电力科学研究院
王伟wangwei华北电力大学 电子与电气工程学院
摘要点击次数: 1640
中文摘要:
      国家智能电网的建设已全面展开,设备智能化进程加快,而高压开关时间参数的测量仍然采用传统的离线方式进行,增加了设备停电时间,降低了电网供电的可靠性。文章旨在研究高压开关开断与闭合的射频信号特征,为高压开关特性射频法检测系统样机开发提供参考依据。最终开发了高压开关特性射频法检测系统样机,包括选择射频天线的形式与频带、数据采集解决方案,编制检测与评估软件。实验结果表明,高压开关开断与闭合过程中辐射出射频信号的频域很广,上限可达2 GHz。文中研制的样品机器,脉冲间隔时间测量不确定性,幅值一致性均得到工程的实际要求。
英文摘要:
      The construction of national smart grid has been carried out, and the process of equipment intellectualization has been accelerated. However, the measurement of time parameters of high-voltage switch still adopts the traditional off-line mode, which increases the outage time of equipment and reduces the reliability of power supply. Firstly, this paper studies the characteristics of the RF signal of the high-voltage switch in the process of switching and closing, which provides a reference for the development of the prototype of the high-voltage switch characteristic RF detection system. Finally, a prototype of high-voltage switching characteristic radio frequency detection system is developed, including the selection of radio frequency antenna form and frequency band, data acquisition solutions, and the development of detection and evaluation software. The experimental results show that the frequency domain of the radio frequency signal emitted by the high voltage switch during the switching and closing process is very wide, and the upper limit can reach 2 GHz. The sample machine developed in this paper, the measurement uncertainty of pulse interval time and the amplitude consistency all meet the practical requirements of engineering.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司