张陈泽宇,李晓华,袁煜文,蔡苏斌,李洁雯,刘对.换相电压简化计算模型及其在换相失败评估中的应用[J].电测与仪表,2021,58(12):125-130.
Zhang-chen Zeyu,Li Xiaohua,Yuan Yuwen,Cai Subin,Li Jiewen,Liu Dui.A Simplified Calculation Model of Commutation Voltage and Its Application in the Evaluation of Commutation Failure[J].Electrical Measurement & Instrumentation,2021,58(12):125-130.
换相电压简化计算模型及其在换相失败评估中的应用
A Simplified Calculation Model of Commutation Voltage and Its Application in the Evaluation of Commutation Failure
DOI:10.19753/j.issn1001-1390.2021.12.018
中文关键词:  高压直流输电  交流故障  换相电压计算模型  换相面积  换相失败评估
英文关键词:LCC-HVDC, AC fault, calculation model of commutation voltage, commutation area, evaluation of commutation failure
基金项目:
                 
作者中文名作者英文名单位
张陈泽宇Zhang-chen Zeyu华南理工大学电力学院
李晓华Li Xiaohua华南理工大学电力学院
袁煜文Yuan Yuwen华南理工大学电力学院
蔡苏斌Cai Subin华南理工大学电力学院
李洁雯Li Jiewen华南理工大学电力学院
刘对Liu Dui华南理工大学电力学院
摘要点击次数: 1138
中文摘要:
      基于准稳态公式理论计算的换相失败评估方法,无法精确评估换相失败边界附近的情况,而基于详细工程模型电磁暂态仿真的方式虽然精确,但效率低且工作量大。为了在兼顾精度的同时提升换相失败风险评估效率,基于等值网络的状态方程,本文提出了交流故障后直流系统换相电压的简化计算模型,并进一步应用计算结果进行换相失败风险评估。通过仿真软件PSCAD/EMTDC,从换相面积和换相失败评估结果两个方面,验证了计算模型的有效性。结果表明,对于故障后首次换相过程而言,应用本文模型求得的换相面积与仿真所得换相面积相差甚小,且应用该模型能较为高效精确地评估直流发生换相失败的情况。
英文摘要:
      The evaluation method of commutation failure based on the quasi-steady-state formula cannot accurately estimate the situation nearby the commutation failure boundary. And the method based on the electromagnetic transient simulation of the detailed engineering model is accurate, but the efficiency is low and the workload is large. In order to improve the efficiency of commutation failure risk assessment and take into account the accuracy, based on the state equation of the equivalent network, this paper proposes a simplified calculation model of the commutation voltage in the DC system after AC fault, and applies the calculation results to the risk assessment of commutation failure. Through the simulation software PSCAD/EMTDC, the validity of the calculation model is verified from two aspects: the commutation area and the evaluation results of commutation failure. The simulation results show that the commutation area obtained by the model is very close to the commutation area obtained by the simulation software in the first commutation process after the AC fault. And applying this model can estimate the situation of commutation failure with accuracy and efficiency.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司