李一鸣,田付强,刘雪梅,穆勇,徐丽华,张运.氧化锌避雷器绝缘老化与检测技术实验研究[J].电测与仪表,2022,59(11):139-146.
liyiming,tianfuqiang,liuxuemei,muyong,xulihua,zhangyun.Experimental Study on Insulation Aging and Detection Technology of Zinc Oxide Arrester[J].Electrical Measurement & Instrumentation,2022,59(11):139-146.
氧化锌避雷器绝缘老化与检测技术实验研究
Experimental Study on Insulation Aging and Detection Technology of Zinc Oxide Arrester
DOI:10.19753/j.issn1001-1390.2022.11.019
中文关键词:  氧化锌避雷器  阻性电流  绝缘状态评估
英文关键词:MOA, resistive current, Insulation Status Evaluation
基金项目:
                 
作者中文名作者英文名单位
李一鸣liyiming北京交通大学
田付强tianfuqiang北京交通大学
刘雪梅liuxuemei国网冀北电力有限公司唐山供电公司
穆勇muyong国网冀北电力有限公司唐山供电公司
徐丽华xulihua国网冀北电力有限公司昌黎县供电分公司
张运zhangyun北京交通大学
摘要点击次数: 1486
中文摘要:
      为了对避雷器在运行过程中的绝缘状态进行评估,本文在实验室搭建了避雷器高压实验系统,模拟避雷器运行工况老化,测试电压5kV~13.6kV电压,温度20℃~60℃,相对湿度20%~80%,盐密度20g/L~160g/L。此外,对避雷器在200℃下进行了100h加速热老化实验。实验过程中实时监测氧化锌避雷器泄漏电流及其阻性分量并以其为主要特征量,建立BP神经网络模型,以泄露电流及其阻性分量和环境变量作为输入量,绝缘状态为输出量,对避雷器老化过程中的绝缘状态进行评估。实验测试结果表明,该模型对绝缘状态评估的相对误差在1%以下,并能有效去除环境因素对避雷器绝缘状态评估的干扰。
英文摘要:
      In order to evaluate the insulation state of the arrester during operation. A a high-voltage experimental system of arrester is set up in the laboratory to simulate the aging of arrester under operating conditions. The test voltage is 5kV ~ 13.6kv, the temperature is 20 ℃ ~ 60 ℃, the relative humidity is 20% ~ 80%, and the salt density is 20g / L ~ 160g / L. In addition, the accelerated thermal aging test of arrester at 200 ℃ for 100h was carried out. During the experiment, the leakage current and its resistance component of ZnO arrester are monitored in real time and taken as the main characteristic quantity. The BP neural network model is established. The leakage current and its resistance component and environmental variables are taken as the input quantity and the insulation state is taken as the output quantity to evaluate the insulation state during the aging process of arrester.The experimental results show that the relative error of the model is less than 1%, and it can effectively remove the interference of environmental factors on the evaluation of the insulation state of the arrester.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司