• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
万立宇,应栋子,辛洁晴.HPLC采集环境下的居民台区换相策略研究[J].电测与仪表,2021,58(10):23-28.
WAN LIYU,YING DONGZI,XIN JIEQING.Study on Cell Commutation Strategy in Residential Transformer Zones under the HPLC Metering Environment[J].Electrical Measurement & Instrumentation,2021,58(10):23-28.
HPLC采集环境下的居民台区换相策略研究
Study on Cell Commutation Strategy in Residential Transformer Zones under the HPLC Metering Environment
DOI:10.19753/j.issn1001-1390.2021.10.004
中文关键词:  小区配电网  换相策略  线损分析  节能  物联网
英文关键词:District Distribution Network  Commutation strategy  Line loss analysis  Energy conservation  Internet of things
基金项目:国家自然科学基金重点资助项目(51777121)
        
作者中文名作者英文名单位
万立宇WAN LIYU上海交通大学
应栋子YING DONGZI上海交通大学
辛洁晴XIN JIEQING上海交通大学
摘要点击次数: 1461
中文摘要:
      居民台区线损主要由三相负荷不平衡引起,但由于楼内三相线路长短不一,线损最小状态不一定对应单元楼三相进线负荷最平衡的状态,传统以进线负荷平衡为目标的换相策略的降损效果有限。HPLC采集系统可获取用户相位和楼层线阻抗信息,为直接以台区线损最小化为目标的楼内用户换相策略的实施提供了可能性。针对该采集环境,本文将居民台区低压配网视为楼内层、小区层两个环节,先以楼层线损耗最小和换相次数最少为目标优化楼内用户换相策略,随后以小区层线损最小和换相次数最少为目标构建门洞进线换相策略,从楼内、小区两个环节挖掘降损潜力。针对上海某居民台区的算例分析表明,所提换相策略能使台区配网损耗降低17.2%,较仅通过门洞进线换相提高三相负荷平衡度的做法降低网损10.83个百分点。
英文摘要:
      Line loss in residential transformer zones is mainly caused by the imbalance of the three-phase loads. However, due to the difference of the three-phase line lengths in the building, the minimum-line-loss state does not necessarily correspond to the most load-balanced state at the incoming point of the building. So, traditional commutation strategies which aim at the balance of the incoming line loads are of limited loss-reduction effects. Under the HPLC metering environment, user phases and floor line impedances can be concluded. This makes it possible to carry out user commutation in a building directly with the objective of minimizing the line loss in the residential transformer zone. In this paper, low-voltage distribution network of a residential transformer zone is divided into two parts: an inner building part and a community part. First, user commutation strategy in the building is optimized with the objective of minimizing floor line losses and commutation times. Second, building commutation strategy is constructed to further minimize the line losses and commutation times in the community part. Case study towards a residential area in Shanghai shows that the proposed commutation strategy can reduce the distribution network loss by 17.2%, which is 10.83 percentage points lower than the way of only improving the balance of the three-phase incoming loads of the buildings.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司