• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
伍祥,陈旭,张利花,华玉婷,程志强,张超.同塔双回超高压输电线路功率负损耗成因分析[J].电测与仪表,2022,59(4):152-158.
Wu Xiang,Chen Xu,Zhang Lihua,Hua Yuting,Cheng Zhiqiang,Zhang Chao.Negative power loss analysis of double-circuit EHV transmission lines on the same tower[J].Electrical Measurement & Instrumentation,2022,59(4):152-158.
同塔双回超高压输电线路功率负损耗成因分析
Negative power loss analysis of double-circuit EHV transmission lines on the same tower
DOI:10.19753/j.issn1001-1390.2020.04.022
中文关键词:  功率负损耗  同塔双回  超高压输电线路  计量误差  电磁耦合
英文关键词:negative power loss, double-circuit on the same tower, EHV transmission lines, measurement error, electromagnetic coupling
基金项目:国网宁夏电力有限公司群众性科技创新(5229DK19000G)
                 
作者中文名作者英文名单位
伍祥Wu Xiang国网宁夏电力有限公司电力科学研究院
陈旭Chen Xu国网宁夏电力有限公司电力科学研究院
张利花Zhang Lihua国网宁夏电力有限公司电力科学研究院
华玉婷Hua Yuting中国科学院等离子体物理研究所
程志强Cheng Zhiqiang国网宁夏电力有限公司电力科学研究院
张超Zhang Chao国网宁夏电力有限公司电力科学研究院
摘要点击次数: 1469
中文摘要:
      负线损现象普遍存在于输配电网中,直接关系到供用电双方的经济利益,还会危及电力设备和人身安全。文章用单相输电线路等效模型推导负线损现象与计量装置综合误差的数值关系,得出线损率临界值计算公式。根据电磁感应原理,计及双回线间耦合作用和线路换位情况,推导同塔双回线路的电感矩阵和电容矩阵,可仅归算于双回同相位的两条线间。算例表明,同塔双回线的线损近似与送端电流平方成正比,考虑计量装置的灵敏度,则轻载情况更易出现负线损。计及耦合作用,线损率随送端电流呈“先减小后增大”的变化趋势,且为正值,但若计及计量装置综合误差,则均可能出现负线损。
英文摘要:
      Generally, negative line loss occurs in transmission and distribution networks, which directly affects the economic benefits of both the power supplier and the electricity user. It also harms the power equipment and endangers human’s safety. In this paper, the equivalent model of a single-phase transmission line is used to derive the numerical relationship between the negative line loss and the comprehensive error of the measurement device. The critical value of the line loss rate is obtained. Considering the line transposition, the inductance and capacitance matrices of the double-circuit line on the same tower are derived, according to the law of electromagnetic induction. In the matrices, only the lines with the same phase in the double circuit are contained. The numerical examples show that the line loss is approximately proportional to the square of the current at the sending end. Thus, if the measuring error is considered, the negative line loss is more likely to occur on the light-load operation mode. When the coupling effect is taken into account, the line loss rate decreases and then increases with the current at the sending end. And they are all positive values. However, if the measuring error is taken into account, the negative line losses may occur.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司