王子昂,孟润泉,韩肖清.微电网与配电网间串联补偿变压器直流偏磁抑制策略研究[J].电测与仪表,2022,59(1):127-133.
Wang Ziang,Meng Runquan,Han Xiaoqing.Research on DC Bias Suppression Strategy of Series Compensation Transformer Between Microgrid and Distribution Network[J].Electrical Measurement & Instrumentation,2022,59(1):127-133.
微电网与配电网间串联补偿变压器直流偏磁抑制策略研究
Research on DC Bias Suppression Strategy of Series Compensation Transformer Between Microgrid and Distribution Network
DOI:10.19753/j.issn1001-1390.2022.01.017
中文关键词:  交直流HMG 串联环节 串联补偿变压器 直流偏磁 联合仿真
英文关键词:AC/DC HMG, series link, series compensation transformer, DC bias magnetism, joint simulation
基金项目:国家自然科学基金项目( 项目编号)
        
作者中文名作者英文名单位
王子昂Wang Ziang太原理工大学 电气与动力工程学院
孟润泉Meng Runquan太原理工大学 电气与动力工程学院
韩肖清Han Xiaoqing太原理工大学 电气与动力工程学院
摘要点击次数: 1077
中文摘要:
      通过在交直流混合微电网(hybrid micro-grid, HMG)与配电网间增加串联环节,实现交直流HMG并网运行时,配电网出现故障时较强的电能质量和穿越能力。在配电网故障的开始阶段,串联环节中的串联补偿变压器(the series compensation transformer,SCT)极易产生直流偏磁现象,影响电能质量。一般通过将SCT铁芯设计为两倍额定值的方法来解决这一问题,但这会使得SCT的体积和成本均大幅提高。为保证串联环节在交直流HMG与配电网间可靠、稳定、安全运行,减少SCT的体积和成本,对SCT直流偏磁的抑制十分必要。在分析SCT直流偏磁产生原理的基础上,提出一种通过控制串联环节输出电压首半周期幅值的直流偏磁抑制策略。在Simplorer、Matlab、Maxwell中进行联合仿真,结合实验结果表明,SCT直流偏磁得到有效抑制,验证了所提抑制策略的可行性和有效性。
英文摘要:
      By adding a series link between the AC/DC hybrid micro-grid (HMG) and the distribution network, when the AC/DC HMG is connected to the grid, the power quality and traversing ability of the distribution network in the event of a fault can be achieved. At the beginning of a fault in the distribution network, the series compensation transformer (SCT) in the series link is prone to produce a DC bias phenomenon and affect power quality. This problem is usually solved by designing the SCT core at twice the rated value, but this will greatly increase the size and cost of the SCT. In order to ensure the reliable, stable and safe operation of the series link between the AC/DC HMG and the distribution network, and to reduce the size and cost of the SCT, it is necessary to suppress the DC bias of the SCT. Based on the analysis of the principle of SCT DC bias, a DC bias suppression strategy is proposed by controlling the amplitude of the first half cycle of the output voltage of the series link. Joint simulations were performed in Simplorer, Matlab, and Maxwell. Combined with the experimental results, the SCT DC bias was effectively suppressed, which verified the feasibility and effectiveness of the proposed suppression strategy.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司