• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
张健,黄少锋,李轶凡.统一潮流控制器接入对距离保护的影响及对策[J].电测与仪表,2022,59(5):187-192.
Zhang Jian,Huang Shaofeng,Li Yifan.Analysis of the influence of UPFC on distance protection and the corresponding improved distance protection scheme[J].Electrical Measurement & Instrumentation,2022,59(5):187-192.
统一潮流控制器接入对距离保护的影响及对策
Analysis of the influence of UPFC on distance protection and the corresponding improved distance protection scheme
DOI:10.19753/j.issn1001-1390.2022.05.025
中文关键词:  测量阻抗  偏移圆特性  功率方向元件  统一潮流控制器  距离保护
英文关键词:apparent  impedance, offset  circle configuration, directional  power relay, unified  power flow  controller (UPFC),distance  protection
基金项目:中央高校基本科研业务费专项资金(2019QN107);北京四方自动化有限公司资助项目(KH17010347)
        
作者中文名作者英文名单位
张健Zhang Jian华北电力大学 新能源电力系统国家重点实验室
黄少锋Huang Shaofeng华北电力大学 新能源电力系统国家重点实验室
李轶凡Li Yifan华北电力大学 新能源电力系统国家重点实验室
摘要点击次数: 1470
中文摘要:
      统一潮流控制器(unified power flow controller,UPFC)接入交流系统将改变传输线的潮流,进而对距离保护产生重要的影响。为了研究UPFC的接入对线路距离保护的影响,文中首先建立了UPFC直流侧电压的暂态数学模型,进而推导出在UPFC存在时阻抗元件的测量阻抗表达式。通过定量分析测量阻抗在阻抗复平面上的轨迹变化,发现UPFC的串联侧注入电压改变了阻抗元件的动作边界。为了减小UPFC对距离保护性能的影响,文中提出了距离保护的偏移圆特性,并配合功率方向元件构成完整的距离保护方案。在MATLAB/Simulink中建立了UPFC系统模型,大量仿真结果表明,与基于广义回归神经网络的自适应保护方案相比,文中提出的距离保护方案有更高的可靠性、选择性和灵敏度。
英文摘要:
      Unified power flow controller connected to AC system will change the power flow of transmission line, and then have an important influence on distance protection. In order to analyse the influence of UPFC on the performance of distance protection, the transient mathematical model of DC voltage of UPFC is established, and then the expression of apparent impedance in the presence of UPFC is derived. By analyzing the change of impedance trajectory on the impedance complex plane, it is found that the injected series voltage of UPFC changes the trip boundary of impedance element. In order to eliminate the influence of UPFC on the performance of distance protection, the offset circle characteristic of distance protection is proposed in this paper. The distance protection zone and the directional power relay comprise the distance protection scheme. Finally, the UPFC model is established in Matlab/Simulink. Various simulations show that the distance protection scheme proposed in this paper has higher reliability, selectivity and sensitivity compared with the adaptive protection scheme based on generalized regression neural network.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司