• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
徐玉琴,许佳敏.基于暂态零序电流图像识别的配电网单相接地故障区域定位[J].电测与仪表,2023,60(3):33-39.
XU Yuqin,XU Jiamin.Single-phase ground fault area location of distribution network based ontransient zero-sequence current image recognition[J].Electrical Measurement & Instrumentation,2023,60(3):33-39.
基于暂态零序电流图像识别的配电网单相接地故障区域定位
Single-phase ground fault area location of distribution network based ontransient zero-sequence current image recognition
DOI:10.19753/j.isssn1001-1390.2023.03.005
中文关键词:  单相接地故障  暂态零序电流  图像识别  卷积神经网络  故障区域定位
英文关键词:single-phase  ground fault, transient  zero-sequence  current, image  recognition, convolutional  neural network, fault  area location
基金项目:青年科学基金项目(51807059)
     
作者中文名作者英文名单位
徐玉琴XU Yuqin华北电力大学 电气与电子工程学院
许佳敏XU Jiamin华北电力大学 电气与电子工程学院
摘要点击次数: 1185
中文摘要:
      为了提高配电网单相接地故障的定位准确率,提出一种基于暂态零序电流图像识别的配电网单相接地故障区域定位方法。首先,通过PSCAD实现故障仿真,构建卷积神经网络(CNN)学习所需图像集。然后,根据单相接地故障的两值性和分化性特征,基于Python编程进行图像预处理,采用VGGNet11网络结构对预处理后的字节形式故障样本进行训练,得到故障区域定位模型,并可视化分析模型分类效果。典型10kV配电网模型数字仿真及现场试验均表明,所提方法能够准确实现故障区域定位,不受系统接地方式、故障电阻和初始相角的影响。可采用暂态录波型故障指示器采集线路暂态零序电流,信号获取方便。
英文摘要:
      In order to improve the positioning accuracy of single-phase grounding faults in distribution network, a single-phase ground fault area location based on transient zero-sequence current image recognition is proposed. First, the fault simulation is realized by PSCAD to construct the image set required for Convolutional Neural Network(CNN) learning. Then, according to the ambiguity and differentiation characteristics of single-phase ground faults, image preprocessing based on Python programming. The pre-processed byte-form fault samples are trained by the VGGNet11 network structure to obtain a fault region localization model, and the classification effect is visually analyzed. Digital simulation and field tests of a typical 10kV distribution network model show that the proposed method can accurately locate the fault area without being affected by the system grounding mode, fault resistance and initial phase angle. The transient oscilloscope type fault indicator can be used to collect the transient zero sequence current of the line, and the signal acquisition is convenient.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司