林志超,罗步升,宋志坚.基于非参数估计的电压暂降下敏感设备故障率评估[J].电测与仪表,2023,60(6):86-95.
Lin Zhichao,Luo Busheng,Song Zhijian.Fault Rate Assessment of Voltage Sag Sensitive Equipment Based on Nonparametric Assessment[J].Electrical Measurement & Instrumentation,2023,60(6):86-95.
基于非参数估计的电压暂降下敏感设备故障率评估
Fault Rate Assessment of Voltage Sag Sensitive Equipment Based on Nonparametric Assessment
投稿时间:2020-02-28  修订日期:2020-02-28
DOI:10.19753/j.issn1001-1390.2023.06.013
中文关键词:  (2)电能质量  电压暂降  设备故障率评估  概率密度  电压耐受曲线
英文关键词:power quality, voltage sag, equipment fault rate  assessment, probability density, voltage tolerance curve
基金项目:中国南方电网有限责任公司科技项目(GDKJXM20172957)
        
作者中文名作者英文名单位
林志超Lin Zhichao广东电网有限责任公司惠州供电局
罗步升Luo Busheng广东电网有限责任公司惠州供电局
宋志坚Song Zhijian广东电网有限责任公司惠州供电局
摘要点击次数: 178
中文摘要:
      电压暂降下敏感设备的故障率是电网侧和用户侧开展电压暂降治理的重要参考信息。文中提出一种基于非参数估计的敏感设备故障率评估方法。针对电压暂降的幅值、持续时间和波形点等特征具有独立性,基于非参数估计方法,提出电压暂降特征量的概率密度函数评估方法,从而构建不确定区域内电压耐受曲线拐点位置分布的联合概率密度函数。将不确定性区域受影响情况分为三个区域进行分析,提出基于U-T联合概率密度函数的电压暂降下敏感设备故障率评估模型。搭建PC机的电压耐受能力测试平台,基于测试数据验证所提算法。构建理论仿真模型并接入IEEE标准测试系统仿真,以仿真数据验证所提方法。基于实测数据与仿真数据,与现有算法进行对比,证明了所提方法的正确性和实用性。
英文摘要:
      The fault rate of voltage sag sensitive equipment is an important reference information for power grid side and user side to carry out voltage sag mitigation measure. This paper presents a nonparametric estimation method for fault rate assessment of sensitive equipment. In view of the independence of the magnitude, duration and point on wave of the voltage sag, a method for evaluating the probability density function of the characteristic quantity of voltage sag is proposed based on the non-parametric estimation method, so as to construct the joint probability density function of the position distribution of the infection point of the voltage tolerance curve in the uncertain area. The affected conditions of the uncertainty region are divided into three regions for analysis, and the fault rate evaluation model of the sensitive device based on the u-t joint probability density function is proposed. Build a PC voltage tolerance test platform and verify the proposed method based on the test data. A theoretical simulation model is built and connected to IEEE standard test system to verify the proposed method with simulation data. Based on the measured data and the simulated data, the correctness and practicability of the proposed method are proved by comparing with the existing method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 环球表计
  • 自动化仪表网
  • 网站首页
  • 期刊介绍
    • 历史简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编简介
    • 主任委员简介
    • 编委名单
  • 学术动态
  • 投稿指南
    • 投稿须知
    • 投稿步骤
    • 版权转让协议范文(规范细则)
    • 写作指南
    • 常见问题
    • 稿件处理流程
    • 同行评议制度
    • 学术不端论文的认定和处理方法
    • 出版道德声明
    • 学术论文编写规则
  • 订阅指南
    • 期刊订阅
  • 广告服务
  • 历年目次
  • 开放获取
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
版权所有    电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司